background image

 7

IQAN-LST Technical Overview

Appendix A

Instruction book, IQAN-LST

Appendix A

IQAN-LST Technical Overview

Absolute maximum rating

s

T

A

 = +25 °C (unless otherwise specified)

The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be subjected without damage. This doesn't imply
that the device will function at these extreme conditions, only that, when these damage. This doesn't imply that the device will function at
these extreme conditions, only that, when these conditions are removed and the device operated within the “Recommended Operating Con-
ditions”, it will still be functional and its useful life won't have been shortened.

Environmental ratings

System

T

A

 = +25 °C, V

S

 = 5 V (unless otherwise specified)

Ambient temperature, T

A

-40 to 85 °C

Storage temperature

-40 to 100 °C

Max, overvoltage on V

S

 and VOUT pins

8.5 V (14V for max 10 minutes)

External magnetic field

2.5 mT

Climate

Enclosure, water & dust protection
Standard
Salt mist
Damp heat cyclic
Damp heat steady state
Heat, operation
Heat, storage
Cold
Change of temperature

IEC 60529:2001, IP65
IEC 60068-2-52:1996 Kb, 72 h
IEC 60068-2-30:1985 Db, +55°C, 95% RH, 6 cycles
IEC 60068-2-78:2001,  +40°C, 93% RH, 21 days
IEC 60068-2-2:1993-01 Bb,  +85°C, 72 hours
IEC 60068-2-2:1993-01 Bb,  +100°C, 72 hours
IEC 60068-2-1:1993-02 Ab,  -40°C, 16 hours
IEC 60068-2-14:1984 Nb,  - 30°C to +85°C, 100 x 4 hours

Mechanical

Random vibration
Bump

IEC 60068-2-64, 10 - 250 Hz, 0.4 G2, 30 h
IEC 60068-2-29:1987 Eb, 40 g, 6 ms, 1000 * 6 dir

EMC

Radiated emission
Conducted susceptibility
Radiated susceptibility
Conducted transients susceptibility
ESD, Operation
ESD, Handling

ISO 13766/ISO 14982
ISO 11452-4, 1 - 200 MHz, 1 kHz, 80% AM, 100 mA
ISO 11452-2, 200-2000 MHz, 1kHz, 80% AM, 100 V/m
ISO 7637-3, Level 3
ISO 10605:2001, 8 kV  (contact), 25 kV (air)
ISO 10605:2001, 4 kV  (contact)

Operating ambient temperature, T

ROC

-40 to 70 °C

Weight

40 g

Содержание IQAN-LST

Страница 1: ...IQAN LST Instruction book Publ no HY33 8303 IB UK Edition 2015 11 19...

Страница 2: ...IQAN LST 1 Introduction 2 Safety symbols 2 2 Precautions 3 General safety regulations 3 3 Product description 5 IQAN LST 5 4 Installation 6 Appendix A 7 IQAN LST Technical Overview 7 Appendix B 9 Dim...

Страница 3: ...ftware The different safety levels used in this manual are defined below WARNING Sections labeled WARNING with a caution symbol in the left margin indicate that a hazardous situation exists If precaut...

Страница 4: ...e fields can in extreme cases cause an unintentional change of speed of the output function NOTICE As much as possible of the welding work on the chassis should be done before the installation of the...

Страница 5: ...ine when first starting up the machine Follow the instructions for function control in the Start up section Safety during maintenance and fault diagnosis WARNING Ensure that the following requirements...

Страница 6: ...IQAN LST has two 2 contactless hall effect sensors that provide mirrored volt age outputs for controlling proportional valve drivers NOTICE In order to increase the safety of the LST the opposing 10...

Страница 7: ...nector kit Parker no 5031097 Housing Amp no 1 963207 1 Plane sealing 4 p Amp no 963208 1 Pin type Amp no 929940 1 Cable 0 75 1 0 mm Seals Amp no 828904 1 Plugs empty pos Amp no 828922 IQAN crimping to...

Страница 8: ...pins 8 5 V 14V for max 10 minutes External magnetic field 2 5 mT Climate Enclosure water dust protection Standard Salt mist Damp heat cyclic Damp heat steady state Heat operation Heat storage Cold Ch...

Страница 9: ...150 mV 2x106 cycles 4500 mV 200 mV 5x106 cycles VOUT maximum linearity error 300 mV VOUT A B maximum difference 375 mV VOUT resolution 12 bits 1 22 mV Response time typical 6 ms Minimum resistive loa...

Страница 10: ...9 Dimensioning of the IQAN LST Appendix B Instruction book IQAN LST Appendix B Dimensioning of the IQAN LST 53 26 8 48 32 units mm...

Страница 11: ...without notice Parker Hannifin Electronic Controls Division SE 435 35 M lnlycke Sweden Tel 46 31 750 44 00 Fax 46 31 750 44 21 www parker com ecd Parker Hannifin Electronic Controls Division 1651 N Ma...