7
IQAN-LST Technical Overview
Appendix A
Instruction book, IQAN-LST
Appendix A
IQAN-LST Technical Overview
Absolute maximum rating
s
T
A
= +25 °C (unless otherwise specified)
The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be subjected without damage. This doesn't imply
that the device will function at these extreme conditions, only that, when these damage. This doesn't imply that the device will function at
these extreme conditions, only that, when these conditions are removed and the device operated within the “Recommended Operating Con-
ditions”, it will still be functional and its useful life won't have been shortened.
Environmental ratings
System
T
A
= +25 °C, V
S
= 5 V (unless otherwise specified)
Ambient temperature, T
A
-40 to 85 °C
Storage temperature
-40 to 100 °C
Max, overvoltage on V
S
and VOUT pins
8.5 V (14V for max 10 minutes)
External magnetic field
2.5 mT
Climate
Enclosure, water & dust protection
Standard
Salt mist
Damp heat cyclic
Damp heat steady state
Heat, operation
Heat, storage
Cold
Change of temperature
IEC 60529:2001, IP65
IEC 60068-2-52:1996 Kb, 72 h
IEC 60068-2-30:1985 Db, +55°C, 95% RH, 6 cycles
IEC 60068-2-78:2001, +40°C, 93% RH, 21 days
IEC 60068-2-2:1993-01 Bb, +85°C, 72 hours
IEC 60068-2-2:1993-01 Bb, +100°C, 72 hours
IEC 60068-2-1:1993-02 Ab, -40°C, 16 hours
IEC 60068-2-14:1984 Nb, - 30°C to +85°C, 100 x 4 hours
Mechanical
Random vibration
Bump
IEC 60068-2-64, 10 - 250 Hz, 0.4 G2, 30 h
IEC 60068-2-29:1987 Eb, 40 g, 6 ms, 1000 * 6 dir
EMC
Radiated emission
Conducted susceptibility
Radiated susceptibility
Conducted transients susceptibility
ESD, Operation
ESD, Handling
ISO 13766/ISO 14982
ISO 11452-4, 1 - 200 MHz, 1 kHz, 80% AM, 100 mA
ISO 11452-2, 200-2000 MHz, 1kHz, 80% AM, 100 V/m
ISO 7637-3, Level 3
ISO 10605:2001, 8 kV (contact), 25 kV (air)
ISO 10605:2001, 4 kV (contact)
Operating ambient temperature, T
ROC
-40 to 70 °C
Weight
40 g