23
4.2 Connection
RE1
RE2
SIN+
SIN -
COS+
COS-
SW1
ON
J4
+V ± V
J 3
PNP
NPN
TA
TB
TC
Relay
output
CAN +
CAN -
CAN
A +
B -
RS485
VCC
KTY
Motor KTY84
Temperature sensor
+15V
GND
-15V
Power supply of
expand card
+15V and GND
can be used as
pressure sensor
power
T
S
R
AC380 V
P
-
B
Braking resistor
Braking unit (optional)
W
V
U
M
CM
DO1
24V
Open-collector
output
DI 1
DI 2
DI 3
DI 4
DI 5
DI 6
DI terminal
Encoder signal and cable colour is
corresponding to TAMAGAWA
resolver TS2640N321E64
Yellow and white
Red and white
Black
Red
Blue
Yellow
AI1
AI 2
AI 3
GND
AO1
Shield layer
Analog output token
Pressure setpoint
Feedback pressure
Flow setpoint
Analog grounding
Wind power cables 2
turns on magnetic ring in
the same direction
Parker IM 20
Servo Drive
J7
NFB
MCCB
Wind power cables 2
turns on magnetic ring in
the same direction
Wind signal cables 2
turns on magnetic ring
in the same direction
AO2
Analog output token
DO2
DO3
DO4
RUN FWD DGT FRQ
M
E
▲
▼
I
O
Matched resistor
Fig 4-2 servo drive standard wiring diagram