![Parker HPD16N Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/parker/hpd16n/hpd16n_user-manual_755776036.webp)
Parker Hannifin S.p.A. - S.B.C. Division HPD N User’s Manual
33
Pr33
Motor rated current
. Unit=% of peak current, range=10.0..50.0%, resolution=0.1%
default=50.0%. Enter motor rated current.
Pr34
Tacho generator emulation output gain
. Default=127. Use parameter 34 to alter
analogue output gain in proportion to speed (terminal 9 on board X2). The analog
output value (Volt) is:
tacho
K
=
⋅
⋅
Pr
Pr
0
34
15875
where: K = 1 if Pr32
≤ 875
K = 4 if 875 < Pr32
≤ 3500
K = 16 if Pr32 > 3500
Pr35
Torque monitor
. Unit=% of peak torque, resolution 0.1%. This parameter indicates
the percentage of torque (or current) that the motor is delivering.
Pr36
Thermal image of motor winding
. Unit=% of reference temperature. This read-
only parameter indicates an estimation of the heat on the innermost windings of the
motor. If the value reaches 100.0 %, which is equal to the nominal value, b41.11
switches to 1 so that current can be limited to the rated value.
Pr37
Thermal image of braking resistor
. Unit=% of nominal temperature. This read-
only parameter indicates an estimation of the heat on the braking resistor. If the value
reaches 100.0 % or more, consider using an external braking resistor.
Pr38 Auxiliary
analogue
output
. Unit=% of 9.76V, default=0, range=±100.0%,
resolution 8 bit. If b40.11 is equal to 1, the auxiliary analogue output will be equal to
976
⋅
Pr38/100 volts.
Pr39 Phase
correction
. This parameter may be used in certain applications with special
motors that are to run also at constant power. Range ±32000, default = 0.
Содержание HPD16N
Страница 1: ...HPD N HPD2N HPD5N HPD8N HPD16N HPD20N HPD24N User s manual rev 8 5 November 2004 software rel 41...
Страница 3: ......
Страница 4: ......
Страница 121: ...Parker Hannifin S p A S B C Division HPD N User s Manual 118...
Страница 125: ......