Maintenance

Instructions

MI-106  Revision  -

Parker Hannifin Corporation

Instrumentation Valve Division

Jacksonville, Alabama

1

F Series Filter

F Series Filter Cross Sectional View

MAXIMUM ALLOWABLE WORKING PRESSURE

Filter  Size

   Brass Body

Stainless Steel Body

       F2, F4, F6,

3000 Psig at 70 °F

    6000 Psig at 70 °F

        F8 & F12

20.7 MPa at 21 °C

    41.4 MPa at 21 °C

F16

3000 Psig at 70 °F

    5000 Psig at 70 °F

20.7 MPa at 21 °C

    34.5 MPa at 21 °C

Always consult your authorized Parker representative if questions arise.  The arrow on the Filter Cap indicates the

normal direction of flow

Содержание F2 Series

Страница 1: ...AXIMUM ALLOWABLE WORKING PRESSURE Filter Size Brass Body Stainless Steel Body F2 F4 F6 3000 Psig at 70 F 6000 Psig at 70 F F8 F12 20 7 MPa at 21 C 41 4 MPa at 21 C F16 3000 Psig at 70 F 5000 Psig at 7...

Страница 2: ...act your authorized Parker representative if any questions arise 2 Clamp the Inline Filter Body next to the flow symbol s arrow at its hex flats Vertical orientation of the Inline Filter in a vise for...

Страница 3: ...ss Steel Body F2 5 8 13 Ft lbs 20 Ft lbs 17 6 N m 27 1 N m F4 3 4 17 Ft lbs 27 Ft lbs 23 0 N m 36 5 N m F6 1 22 Ft lbs 32 Ft lbs 29 8 N m 43 3 N m F8 1 1 4 55 Ft lbs 110 Ft lbs 74 4 N m 148 9 N m Figu...

Страница 4: ...Y 1 Make certain all parts are free of dirt or other contamination before starting reassemble of the Filter 2 Apply a moderate amount of lubricant to the face of the Seal as consistent with the Filter...

Страница 5: ...vision Jacksonville Alabama MI 106 5 Figure 4 Inline Filter with Sintered Element Exploded View purchased after July 1 1993 Figure 5 Inline Filter with Wire Cloth Element Cross Sectional View Figure 6...

Страница 6: ...valves purchased after July 1 1993 WIRE CLOTH FILTER ELEMENTS The disassembly and reassemble of Filters that have wire cloth elements is the same as valves with the sintered elements The only differe...

Страница 7: ...eal face contact and O Ring seal compression into the UltraSeal groove VACUSEAL CONNECTIONS 1 A positive seal is obtained by advancing the Nut 1 8 turn from the finger tight position 2 Anew gasket sho...

Страница 8: ...e variety of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the final selection of the products and...

Отзывы: