Parker EO2-FORM Скачать руководство пользователя страница 5

E

Tube assembly

E25

Catalogue 4100-5/UK

3

4

2

1

90

°

3

2

1

EO2-FORM assembly instructions

Installation

Tube must fit without tension

Assembly check

Check assembly result

Incorrect assemblies
must be scrapped

Check contour: Contact surface
for sealing ring (arrow) must be
flat, at right angle to tube

Place sealing ring (DOZ) onto
tube-end

Sealing surface (arrow) must be
free of scratches and damage

Threads of stainless steel fittings
must be lubricated

EO-NIROMONT is a special high-
performance lubricant for
stainless steel fittings

Tube must fit without tension

Assemble fitting until wrench-tight
(without spanner extension)

Then tighten fitting firmly by

1/6 turn (1 flat)

Recommended to use spanner

extension for sizes over 20 mm
O.D. 

(see chart)

Incorrect assembly reduces
performance and reliability of the
connection

Check outer diameter Ø...

(see chart)

Incorrect tube-ends must be
scrapped. Tools must be cleaned
and checked

Size

Spanner length

H [mm]

22-L

400

28-L

20-S

500

35-L

25-S

800

42-L

30-S

1000

38-S

1200

Spanner length

Tube Ø-

min Ø

max Ø

Series

[mm]

[mm]

6-L/S

9

10.2

8-L/S

11

12.2

10-L

13.2

14.2

12-L

15.2

16.2

15-L

18.5

20.2

18-L

21.5

24

22-L

26

27.7

28-L

32

33.7

35-L

39.5

42.5

42-L

46.5

49.5

10-S

13.5

15.5

12-S

15.5

17.5

16-S

19.5

21.5

20-S

24.5

27.5

25-S

30

34

30-S

35

39

38-S

43

47

Tube OD check

Отзывы: