background image

DPS70 

 

 

About the DPS70 

 

1.1.  Diagram conventions 

The following symbols are used in the schematic diagrams in this document: 

Symbol 

Meaning 

 

General input 

 

General output 

 

Frequency input 

 

Analog input 

 

Frequency sensor 

 

Pulse sensor 

 

Resistive sensor 

 

General sensor 

 

Application switch 

 

Load 

 

Pull-down resistor 

Содержание DPS70

Страница 1: ...Display Panel Standard DPS70 With 7 touchscreen U s e r G u i d e UG DPS70 1020000 201906 003 ...

Страница 2: ...ng the final selection of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidi...

Страница 3: ... Analog Input Configuration Options 7 2 1 3 Analog Input Installation Connections 7 2 2 DPS70 Frequency Inputs 7 2 2 1 DPS70 Frequency Input Capabilities 8 2 2 2 DPS70 Frequency Input Installation Connections 8 2 3 Digital Inputs 9 2 3 1 DPS70 Digital Input Capabilities 9 2 3 2 Digital Input Installation Connections 10 2 4 Video Inputs 11 2 4 1 Video Input Capabilities 11 3 Outputs 12 3 1 High Sid...

Страница 4: ... 1 CAN 18 5 2 USB Host 18 5 3 USB Device 19 5 4 RS232 19 5 5 Ethernet 19 6 Display 20 7 Gauge Area 22 7 1 Status Indicator LEDs 22 7 2 Analog Gauges 23 7 2 1 Gauge Backlighting 23 7 3 Buzzer 24 7 4 Real Time Clock 24 8 Connectors 25 8 1 Pinouts 26 9 Mounting 28 9 1 Mechanical requirements 28 9 2 Dimensions 29 10 Environmental Protection 30 11 Glossary 31 12 Index 42 ...

Страница 5: ...ument over the course of its publication history Release Date Description of Change Rev 001 First release of this document February 2014 Rev 002 Minor edits from User Guide review meeting 2014 02 25 and 2014 03 03 Rev 003 Remove 3rd CAN bus not implemented 2019 06 05 Publication History ...

Страница 6: ...equipment or degradation of signal When you see these symbols follow the instructions carefully and proceed with caution General safety regulations Work on the hydraulics control electronics may only be carried out by trained personnel who are well acquainted with the control system the machine and its safety regulations Follow the manufacturer s regulations when mounting modifying repairing and m...

Страница 7: ...trol system 1 Disconnect the electrical connections between the system and external equipment 2 Disconnect the negative cable from the battery 3 Disconnect the positive cable from the battery 4 Connect the welder s ground wire as close as possible to the place of the welding Construction regulations The vehicle must be equipped with an emergency stop which disconnects the supply voltage to the con...

Страница 8: ...erified Do not start the machine if anyone is near the machine Safety during maintenance and fault diagnosis Before performing any work on the hydraulics control electronics ensure that The machine cannot start moving Functions are positioned safely The machine is turned off The hydraulic system is relieved from any pressure Supply voltage to the control electronics is disconnected ...

Страница 9: ...f vehicle cameras Four of the video inputs can be simultaneously viewed on the display The fifth input is recommended to be dedicated for the backup camera The communication options to the cluster are USB host USB device RS232 10 100 Ethernet and 2 CAN buses Figure 1 DPS70 display cluster The DPS70 is controlled by software Contact your Parker Vansco Account Representative for more details about t...

Страница 10: ...sed typically for a fault alarm but could also be used for other sounds The DPS70 can monitor up to 26 inputs 10 analog inputs 2 frequency inputs 9 digital inputs 3 have option to be populated as wake up power control 5 video inputs The DPS70 has 2 outputs 2 high side outputs The DPS70 has a sensor supply output 1 sensor supply output 5 V 100 mA The DPS70 can detect the following faults on the out...

Страница 11: ...al describes the hardware components of the DPS70 but does not explain how to write or configure the software For more information about software refer to the appropriate software manual or contact your Parker Vansco Account Representative ...

Страница 12: ...he following symbols are used in the schematic diagrams in this document Symbol Meaning General input General output Frequency input Analog input Frequency sensor Pulse sensor Resistive sensor General sensor Application switch Load Pull down resistor ...

Страница 13: ...equirements to be met by the DPS70 1 2 1 Regulatory Compliance This product will be regulatory compliant to the following Restriction of Hazardous Substances RoHS Compliant to Directive 2002 95 EC Waste Electrical and Electronic Equipment WEEE Compliant to Directive 2002 96 EC 1 2 2 Declaration of Regulatory Compliance The product will be declared RoHS Compliant to IPC 1752 Class 1 ...

Страница 14: ...nalog Input 1 to Analog Input 10 All of the analog inputs are biased to a midpoint with pull up resistor This allows them to be used as a tri state input 2 1 1 Analog Input Capabilities The following table provides specifications for the analog inputs Analog Input Specifications Item Min Nom Max Unit Input voltage range 0 6 6 V Input pin capacitance 05 µF Pull up down resistance 10 k Response to s...

Страница 15: ...rom affecting the analog input signals Internal to product 5 Vdc Sensor Supply Sensor Ground Sensor Figure 2 Analog input system noise connection Note It is important that the sensor supply does not connect to another power source external to the DPS70 The sensor ground should also not be connected to any other ground on the vehicle 2 2 DPS70 Frequency Inputs There is one type of frequency input i...

Страница 16: ... Coupled Frequency Input Specifications Item MIN NOM MAX UNIT Negative going switching threshold 1 56 V Positive going switching threshold 3 82 V Input capacitance at pin 005 µF Over voltage 36 V Frequency accuracy 5 Frequency range note 1 0 10000 Hz Pull up down resistor 10 kΩ Note 1 Electrically signals to 0 are possible but the software will limit the minimum measureable frequency 2 2 2 DPS70 F...

Страница 17: ...d on the vehicle 2 3 Digital Inputs The DPS70 has 9 digital inputs Digital Input 1 to Digital Input 3 Digital Input 4 to Digital Input 9 All of the digital inputs have a 1 2 k resistor that provides the path for the wetting current The resistor is connected to ground or VBATT depending on the active state of the input The DPS70 has 2 types of digital inputs Hardware configurable active high or act...

Страница 18: ...ltage 36 V Inductive load protection no Input capacitance 05 µF Response time to step input 1 5 ms Input high threshold 4 62 V Input low threshold 1 98 V Active High Configuration Input resistance to ground 1 2 kΩ High threshold 9 V 1 kΩ Low threshold 16 V 8 2 kΩ Active Low configuration Input resistance to 3 3 V note 1 1 2 kΩ High threshold 700 Ω Low threshold 200 Ω Note 1 Active low has pull up ...

Страница 19: ...e High Digital Input Battery Application Switch Figure 4 Active high digital input 2 4 Video Inputs The DPS70 accepts 5 NTSC PAL camera inputs via BNC video connectors on the rear of the unit Inputs 1 and 2 feed are multiplexed to the same input of the video decoder Video inputs 3 4 and 5 have dedicated decoder inputs Up to 4 video feeds can be shown on the display simultaneously 2 4 1 Video Input...

Страница 20: ...r various fault conditions 3 1 1 High Side Output Capabilities All high side outputs come with internal flyback diodes that provide protection when driving inductive loads When a high side output is used as a PWM signal a pulsed output signal is provided by the DPS70 where the percentage of time that the output is on vs off is determined by the duty cycle of the signal The duty cycle is determined...

Страница 21: ... configured with a software controlled 10 k pull up resistor to battery for open load detection in the off state 3 1 3 High Side Output Installation Connections When connecting the high side outputs note that The high side output is connected to an internal bus bar which can be connected to a 12 V or 24 V battery The high side output can provide switched battery power to any load type in a vehicle...

Страница 22: ... to turn the output on again 3 1 4 High Side Output Diagnostics and Fault Detection The DPS70 high side outputs have the ability to report many different fault conditions They are protected against short circuit overcurrent open load short to battery and short to ground faults 3 1 4 1 Short Circuit Short circuit faults occur when a low side output pin is shorted to battery and produces an output c...

Страница 23: ...thout current sense must be off to detect an open load fault 3 1 4 4 Open Load Open load faults occur when a low side output pin is open circuit not connected to a load The use of this feature operates as defined by the programmer The low side output circuit uses a small amount of current on the output pin to determine if an open load condition exists Note Low side outputs must be on to detect an ...

Страница 24: ...e following table provides specifications for the DPS70 s sensor supply output Sensor Supply Output Specifications Item Min Nom Max Unit Output voltage 4 75 5 0 5 25 V Current limit 100 mA Over voltage 36 V 3 2 2 Sensor Supply Output Installation Connections The sensor supply and the sensor ground are intended to be the power source for external sensors It is important that these power signals do ...

Страница 25: ... The following table provides specifications for the DPS70 s power supply Power Specifications Item Min Nom Max Units Input voltage for normal operation 9 32 V Minimum cranking voltage note 1 7 V Overvoltage protection DC 36 V Reverse battery protection note 2 36 V Typical current at 12 V note 3 700 mA Off state current VBATT of 12 V 2 mA Rating of External Fuse 10 A Note 1 The unit will operate b...

Страница 26: ...or the CAN CAN Specification Item Min Nom Max Unit Over voltage 30 V On board terminator optional 120 Baud rate 125 250 500 Kbps Capacitance 33 pF 5 2 USB Host The DPS70 supports one USB Host port capable of high speed USB 2 0 The USB Host port will support a device with current drain not exceeding 500mA The following table provides specifications for the USB host USB Host Specifications Item Min ...

Страница 27: ...ull Speed 12 Mbps Capacitance of I O to ground 2 5 3 5 pF Reverse standoff voltage note 1 5 V Note 1 USB connectors are not rated to survive a short to vehicle battery 5 4 RS232 The UART is an external serial port used as a 3 wire serial interface Rx Tx Gnd operating up to 115200 8 N 1 The following table provides specifications for the RS232 RS232 Specifications Item Min Nom Max Unit Communicatio...

Страница 28: ...ifications Item Min Nom Max Unit Size Aspect ratio 16 9 Screen size 7 inch Active area 152 4x91 44 mm Resolution 800x480 pixels Viewability Viewing angle CR 10 U D 178 degrees Viewing angle CR 10 R L 178 degrees Color 8 bit Contrast ratio CR 560 800 Brightness 360 450 cd m Backlight lifetime 30 000 hrs Environmental Operating temperature 30 80 C Storage temperature 30 85 C Interface LVDS LVDS cloc...

Страница 29: ...vides the touchscreen specifications for the DPS70 s display Touchscreen Specifications Item Min Nom Max Unit Surface hardness 6 7 H Transmissivity 90 Operating temperature 20 70 C Storage temperature 30 85 C Impact rating IK06 Response time 60 ms ...

Страница 30: ...motor gauges 7 1 Status Indicator LEDs There are 26 status LEDs telltales on the DPS70 The brightness of the telltales can be adjusted through software This adjustment controls the brightness of all of the telltales and the analog gauge backlighting together Figure 6 DPS70 telltale LEDs and color locations 7 Gauge Area ...

Страница 31: ...s on the DPS70 They are implemented using stepper motors and can be micro stepped Micro stepping results in pointer movement of 1 12 per step The motors have internal stops and the pointers are zeroed on each power cycle The following table has the specifications for the analog gauges Analog Gauge Specifications Item Min Nom Max Unit Sweep range small gauge 225 degrees Sweep range large gauge 250 ...

Страница 32: ...vel 10 cm note 1 110 dBa Voltage 1 12 36 V Operating temperature range 40 85 C Storage temperature range 40 85 C Note 1 SPL at resonant frequency with product not installed in vehicle and the distance is off the rear cover 7 4 Real Time Clock The real time clock is incorporated in the gauge co microprocessor The primary power for the clock is from the direct battery connection If the direct batter...

Страница 33: ...e Molex MX150 connectors are used to interface the DPS70 to the vehicle Figure 7 MX150 20 pin connector Mating Connector Part Numbers Connector Shell part no with locking clip Shell part no without locking clip Terminals J1 connector gray 20 pin key option B 334722007 334722002 330012004 18 20 AWG J2 connector black 20 pin key option A 334722006 334722001 330012004 18 20 AWG 8 Connectors ...

Страница 34: ...ach connector J1 Connector Pinout Pin Function 1 Digital input 2 Wake up 2 Digital input 1 Wake up 3 CAN 2 shield 4 CAN 2 low 5 CAN 2 high 6 CAN 1 shield 7 CAN 1 low 8 CAN 1 high 9 Negative battery 10 Positive battery 11 Digital input 3 Wake up 12 Analog input 3 13 Analog input 4 14 Frequency input 1 15 Sensor supply ground 16 Analog input 1 17 Analog input 2 18 High side output 1 19 High side out...

Страница 35: ...ut 4 5 Analog input 10 6 Analog input 9 7 Analog input 8 8 Analog input 7 9 Analog input 6 10 Analog input 5 11 Digital input 5 12 Digital input 6 13 Frequency input 2 14 Digital input 7 15 Negative battery 16 RS232 Rx 17 RS232 Tx 18 Digital input 8 19 Digital input 9 20 Sensor supply 5V ...

Страница 36: ...wing areas of the gauges and LCD A bezel trim ring is recommended usually specified and supplied by the OEM Clip the bezel onto the cluster from the front after the cluster is installed into the dash panel the dash panel must allow clearance for the bezel mounting clip features Refer to Parker product drawing for cluster dimensions and further mounting details For more information contact your Par...

Страница 37: ...ct drawings for more detail For more information contact your Parker Vansco Account Representative 43 9 13 3 92 4 7 0 6X THREADED BRASS INSERTS 8 32 THRU 13 0 2X 15 0 183 0 2X 219 0 423 0 18 0 12 3 153 4 2X 191 0 124 0 2X 120 0 28 8 VIEWING AREA UNITS mm FRONT VIEW BEZEL NOT SHOWN REAR VIEW BEZEL NOT SHOWN Figure 9 DPS70 dimensions without bezel ...

Страница 38: ...meet stringent industry standards A summary of tested specifications was not available when this document was published The information will be included in future editions Please contact your Parker Vansco representative for more details 10 Environmental Protection ...

Страница 39: ...onversion distortion that occurs when the analog signal being sampled has a frequency greater than half the sample rate An example of aliasing is the wagon wheel effect often seen in films in which a spoked wheel appears to rotate differently from its true rotation amplified A circuit that applies a gain with a value greater than one 1 to a measured signal which is typically used with analog input...

Страница 40: ...A subsystem that transfers data between components within a computer or between computers bus bar A strip or bar of copper brass or aluminum that conducts electricity CAN bus See controller area network CAN bus CAN high The positive wire in a shielded twisted pair cable which when connected with a CAN low provides a complete CAN differential signal CAN low The negative wire in a shielded twisted p...

Страница 41: ...software to measure the amount of current provided by the outputs This circuit is typically connected to an analog input that is connected to the microprocessor Also known as current sense or current sensing current feedback control Varying the duty cycle of an output so that the output provides a desired amount of current to the load current sensor A device that detects electrical current in a wi...

Страница 42: ...onents duty cycle The time that a device spends in an active or operative state expressed as a fraction or percentage of the total cycle time start operate stop electromagnetic compatibility EMC The ability of a component within a system to function correctly despite electromagnetic interference propagated by other components in the system electromagnetic susceptibility The ease with which a devic...

Страница 43: ... a low side switch in order to provide a load having both a battery voltage and a ground harness address pins The pins a product uses to identify itself within a system H bridge A combination of two half bridge circuits used together to form one circuit H bridges provide current flow in both directions on a load allowing the direction of a load to be reversed high side output An output that provid...

Страница 44: ...ntal rungs each representing a logical rule between them Ladder programs for Parker Vansco products are written using Vansco Multiplexing Module Software VMMS leakage current Current that flows when the ideal current is zero LIM16H A light indicator module with 16 inputs that are hardwired to telltales load Any component that draws current from a module and is typically switched on and off with ou...

Страница 45: ...ginal signal contains no frequencies at or higher than one half the sampling frequency open load The disconnection of a load from an output often because of a broken or worn wire or connector pin overcurrent A fault state that occurs when a load draws more current than specified for an output which results in the output shutting down to protect the circuitry of the product overvoltage A situation ...

Страница 46: ...or analog inputs pull up resistor A resistor that connects an input to a voltage reference so that an open circuit can be recognized by the microprocessor which is typically used on active low digital inputs or analog inputs pulse counter A device that detects and counts pulses occurring on a frequency input for a given period of time pulse width modulation PWM A digital logic circuit programmed t...

Страница 47: ...t pin is connected to battery power potentially resulting in high current flow short to ground A fault state that occurs when an input or output pin is connected to system ground potentially resulting in high current flow sleep mode A low power mode that is assumed by the DPS70 when the voltage on the power control inputs drop below a certain value slew rate 1 The maximum rate at which an output v...

Страница 48: ... the line and causing interference TFT LCD See thin film transistor liquid crystal display thin film transistor liquid crystal display TFT LCD A liquid crystal display in which each pixel of the screen is powered separately by a transistor transflective liquid crystal display A liquid crystal display that reflects and transmits light permitting readability in varying light conditions transient A s...

Страница 49: ...em through software VMMS Vansco Multiplexing Module Software wake on CAN A method of power control that makes the product turn on when a CAN message is received from another module in the system and turn off as determined by the application software wetting current The minimum current needed to flow through a mechanical switch to break through any film of oxidation that may be on the switch contac...

Страница 50: ...ion of Regulatory Compliance 5 de rating 34 Diagram conventions 4 digital input 34 Digital Input Installation Connections 10 Digital Inputs 9 dimension 34 Dimensions 29 Display 20 DPS70 Digital Input Capabilities 9 DPS70 Frequency Input Capabilities 8 DPS70 Frequency Input Installation Connections 8 DPS70 Frequency Inputs 7 driver hardware 34 driver software 34 duty cycle 34 E electromagnetic comp...

Страница 51: ...installation vii Safety during maintenance and fault diagnosis viii Safety during start up viii Safety symbols vi sample rate 39 sensor power 39 Sensor Supply Output 16 Sensor Supply Output Capabilities 16 Sensor Supply Output Diagnostics and Fault Detection 16 Sensor Supply Output Installation Connections 16 shielded twisted pair cable 39 Short Circuit 14 short to battery 39 Short to Battery 15 s...

Страница 52: ...Display Panel Standard DPS70 User Guide MSG33 5017 IB US ...