404LXR Series Product Manual
Chapter 1 - Introduction
7
Specification Conditions and Conversions
Specifications are Temperature Dependent
Catalog specifications are obtained and measured at 20 Degrees C. Specifications at any other
temperature may
deviate
from catalog specifications. Minimum to maximum continuous operating
temperature range
(with NO guarantee of any specification except motion) of a standard unit before
failure is 5 - 40 Degrees C.
Specifications are Mounting Surface Dependent
Catalog specifications are obtained and measured when the positioner is
fully supported
,
bolted
down
(to eliminate any extrusion deviation), and is mounted to a work surface that has a
maximum
flatness error
of 0.013mm/300mm (0.0005”/ft).
Specifications are Point of Measurement Dependent
Catalog specifications and specifications in this manual are measured from the center of the
carriage, 38 mm above the carriage surface. All measurements taken at any other location may
deviate from these values.
Содержание Daedal 400LXR Series
Страница 8: ...404LXR Series Product Manual Chapter 1 Introduction 8 Assembly Diagrams Strip Seal Version ...
Страница 9: ...404LXR Series Product Manual Chapter 1 Introduction 9 Hardcover Version ...
Страница 11: ...404LXR Series Product Manual Chapter 2 404LXR Series Table Specifications 11 Dimensional Drawings ...
Страница 15: ...404LXR Series Product Manual Chapter 2 404LXR Series Table Specifications 15 ...