background image

Series  C  &  CW  (wall  mounting)  valves  can  be  operated  either 
Normally Closed to pressure or Normally Open to pressure.

Connect  inlet  to  port  “A”  for  normally  closed  valve.  Port  “B”  is 
exhaust.

Connect  inlet  to  port  “B”  for  normally  open  valve.  Port  “A”  is 
exhaust.

Plug exhaust port for 2-way operation.

Port Identifications / Connections

Service Procedures

To disassemble unit, use the following procedure:

To detach the hand toggle, cam head, or button actuator assembly 
from the valve body assembly, remove the 4 pan head screws (using 
a Philips screwdriver). To remove the stem, stem guide, and seals 
from  the  body,  unscrew  the  end  plug  using  a  3/8"  Allen  wrench. 
Then gently press on the “pin” side of the stem until it slides out of 
the body. The stem guide may be removed by pulling axially on the 
radial holes drilled in the stem guide. Be careful not to scratch the 
sealing surfaces or cut the seals.

Thoroughly clean the valve body bore and stem guide, and inspect 
for  possible  nicks,  scratches  and  material  imperfections.  Lightly 
lubricate  the  stem  seals.  (Use  a  non-detergent  hydro-carbon 
based oil or grease.) Replace any o-rings or other seals if they are 
damaged.

The Assembly procedure is the reverse of the above. Tighten the 
end  plug  to  60  in-lbs  and  apply  15-18  in-lbs  of  torque  to  the  pan 
head mounting screws.

If  you  have  questions  concerning  how  to  service  this  unit, 
contact  your  local  authorized  dealer  or  your  customer  service 
representative.

Application Limits

These products are intended for use in general purpose compressed 
air systems only.

Operating Pressure Range:

 

 

psig 

Bar 

kPa

 

Minimum 

    0 

  0 

      0

 

Maximum 

150 

10 

1000

Operating Temperature Range:

 

0°F to 160°F  (-18°C to 71°C)

Installation & Operating Instructions

Valve should be installed with reasonable accessibility for service 
whenever possible - repair service kits are available. Keep pipe or 
tubing lengths to a minimum with inside clean and free of dirt and 
chips. Pipe joint compound should be used sparingly and applied 
only to the male pipe - never into the female port. Do not use PTFE 
tape to seal pipe joints - pieces have a tendency to break off and 
lodge inside the unit, possibly causing malfunction.

Filtered and lubricated air is necessary for maximum valve life and 
minimum maintenance.

Factory Pre-Lubrication - All valves are pre-lubricated at assembly 
with a petroleum based grease.

Valve Operation

These  valves  will  operate  mounted  in  any  position;  they  are  also 
suitable for vacuum service.

A

B

A

B

Normally

Closed

Normally

Open

Installation & Service Instructions
V-222D

C2, C3, C3M1A, C4, C5, C9, C13, C92, C94, 
CW2, CW3, CW3M1A, CW4, CW5, CW9, 
CW13, CW92, & CW94 Series Valves

ISSUED:  November, 2009
Supersedes:   September, 2000

Doc. #V222D,  EN #090938, Rev. 5

Pneumatic Division
Richland, Michigan 49083
269-629-5000

     WARNING

To avoid unpredictable system behavior that can cause personal injury 
and property damage:

•  Disconnect  electrical  supply  (when  necessary)  before  installation, 

servicing, or conversion.

•  Disconnect air supply and depressurize all air lines connected to this 

product before installation, servicing, or conversion.

•  Operate  within  the  manufacturer’s  specified  pressure,  temperature, 

and other conditions listed in these instructions.

•  Medium  must  be  moisture-free  if  ambient  temperature  is  below 

freezing.

•  Service according to procedures listed in these instructions.
•  Installation,  service,  and  conversion  of  these  products  must  be 

performed  by  knowledgeable  personnel  who  understand  how 

 

pneumatic products are to be applied.

•  After installation, servicing, or conversion, air and electrical supplies 

(when  necessary)  should  be  connected  and  the  product  tested  for 

proper  function  and  leakage.  If  audible  leakage  is  present,  or  the 

product does not operate properly, do not put into use.

•  Warnings and specifications on the product should not be covered by 

paint, etc. If masking is not possible, contact your local representative 

for replacement labels.

!

          WARNING

FAILURE  OR  IMPROPER  SELECTION  OR  IMPROPER  USE  OF  THE 
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS 
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This  document  and  other  information  from  Parker  Hannifin  Corporation,  its 
subsidiaries and authorized distributors provide product and/or system options 
for  further  investigation  by  users  having  technical  expertise.  It  is  important 
that  you  analyze  all  aspects  of  your  application,  including  consequences  of 
any  failure  and  review  the  information  concerning  the  product  or  systems 
in  the  current  product  catalog.  Due  to  the  variety  of  operating  conditions 
and  applications  for  these  products  or  systems,  the  user,  through  its  own 
analysis and testing, is solely responsible for making the final selection of the 
products and systems and assuring that all performance, safety and warning 
requirements of the application are met.

The products described herein, including without limitation, product features, 
specifications, designs, availability and pricing, are subject to change by Parker 
Hannifin Corporation and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION 
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS. 
CONTACT YOUR LOCAL REPRESENTATIVE.

!

Safety Guide

 

For more complete information on recommended application guidelines, see 
the Safety Guide section of Pneumatic Division catalogs or you can download 
the 

Pneumatic Division Safety Guide

 at: www.parker.com/safety

Содержание CW Series

Страница 1: ...2 CW12 Valves Installation Service Instructions C6 C7 Valves Installation Service Instructions CS1 CWS1 Valves Installation Service Instructions Flow Control for CC Valves Installation Service Instruc...

Страница 2: ...ent for the two power leads Note Follow all requirements for local and national electrical codes Valve Operation These valves will operate mounted in any position they are also suitable for vacuum ser...

Страница 3: ...PL2481 CWJ137 3 8 NPTF Ports PL2482 Solenoid Identification and Specifications Solenoid Assembly 60 Hz AC 50Hz AC P6972801 120 P6972802 240 P6972806 24 P6972815 110 P6972824 220 When CJ1 or CWJ1 valve...

Страница 4: ...CW94 Series Valves ISSUED November 2009 Supersedes September 2000 Doc V222D EN 090938 Rev 5 Pneumatic Division Richland Michigan 49083 269 629 5000 WARNING To avoid unpredictable system behavior that...

Страница 5: ...L2481 CW37 3 8 NPTF Ports PL2482 Hand Toggle Actuator Assembly Non Locking PL3355 Locking PL2212 Cam Head Assembly Ball C CW2 PL2209 Roller C CW13 PL2422 Heavy Duty Roller Uni Directional C CW92 PL403...

Страница 6: ...and Michigan 49083 WARNING To avoid unpredictable system behavior that can cause personal injury and property damage Disconnect electrical supply when necessary before installation servicing or conver...

Страница 7: ...to service this unit contact your local authorized dealer or your customer service representative Maintenance Trouble Shooting Hints Air Leakage Through Exhaust Ports 1 Check for internal leakage in c...

Страница 8: ...to be increased as line pressure is increased Series C CW wall mounting valves can be operated either Normally Closed to pressure or Normally Open to pressure A B O O A B Normally Closed Normally Ope...

Страница 9: ...orts PL3268 End Plug 1 1 16 Hex P69919 Pressure Actuated Head Ass y PL3244 Part Identification List Item Description 1 Valve Body Assembly 2 Valve Body 3 Stem Retainer Snap Ring 4 Stem O ring 5 Stem 6...

Страница 10: ...2000 Supersedes February 1994 ECN P27805 Pneumatic Division North America Richland Michigan 49083 WARNING To avoid unpredictable system behavior that can cause personal injury and property damage Disc...

Страница 11: ...questions concerning how to service this unit contact your local authorized dealer or your customer service representative Maintenance Trouble Shooting Hints Air Leakage Through Exhaust Ports 1 Check...

Страница 12: ...connected to this product before installation servicing or conversion Operate within the manufacturer s specified pressure temperature and other conditions listed in these instructions Medium must be...

Страница 13: ...ssure then reaches head of work valve and work cylinder advances Return Stroke De energizing clamp valve exhausts head of clamping cylinder and Port 02 of CS1 CS1 returns to ACTUATED position exhausti...

Страница 14: ...eparate flow control valves Air is exhausted through a single valve port requiring only one muffler or piped exhaust connection Adjusting screws with fine threads have metering tapers designed to give...

Страница 15: ...ember 2003 Supersedes May 2003 Doc V 285EP ECN 030951 Rev 6 Pneumatic Division Richland Michigan 49083 WARNING To avoid unpredictable system behavior that can cause personal injury and property damage...

Страница 16: ...unting screws from 1 7 to 2 0 Nm 15 to 18 in lb of torque If body is removed from base torque mounting screws to 11 3 to 14 1 Nm 100 125 in lb of torque when reassembling If you have questions concern...

Страница 17: ...fore installation servicing or conversion Operate within the manufacturer s specified pressure temperature and other conditions listed in these instructions Medium must be moisture free if ambient tem...

Страница 18: ...eals Item 3 Use a nondetergent hydro carbon base oil or grease 6 Insert new spool Item 1 and return spring Item 2 CC10 only from the service kit into the body Spring return end of valve is A 01 If val...

Страница 19: ...nd the product tested for proper function and leakage If audible leakage is present or the product does not operate properly do not put into use Warnings and specifications on the product should not b...

Страница 20: ...LURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document and other information from...

Страница 21: ...ntenance safety and warning requirements are met and that the application presents no health or safety hazards Complying with all existing warning labels and or providing all appropriate health and sa...

Страница 22: ...onents Air leakage Look and listen to see if there are any signs of visual damage to any of the components in the system Leakage is an indication of worn or damaged components Damaged or degraded comp...