Compax3
device description
Single axis devices
18
192-120102 N16 December 2010
In diesem Kapitel finden Sie
State of delivery ............................................................................................................... 18
Meaning of the status LEDs - Compax3 axis controller .................................................... 18
Connections of Compax3S .............................................................................................. 19
Signal interfaces .............................................................................................................. 28
Installation and dimensions Compax3 .............................................................................. 32
3.1
State of delivery
Compax3 is delivered without configuration!
After switching on the 24VDC supply, the red LED is flashing while the green LED
is dark.
Please configure the device with the help of the Windows-Software "Compax3
ServoManager"!
3.2
Meaning of the status LEDs - Compax3 axis controller
Device status LEDs
Right LED (red) Left LED (green)
Voltages missing
off
off
During the booting sequence
alternately flashing
No configuration present.
SinCos
©
feedback not detected.
Compax3 IEC61131-3 program not
compatible with Compax3 Firmware.
no Compax3 IEC61131-3 program
For F12: Hall signals invalid.
flashes slowly
off
Axis without current excitation
off
flashes slowly
Power supplied to axis; commutation calibration
running
off
flashes quickly
Axis with current excitation
off
on
Axis in fault status / fault present / axis energized
(error reaction 1)
flashes quickly
on
Axis in fault status / fault present / axis currentless
(error reaction 2)
on
off
Compax3 faulty: please contact us
on
on
3. Compax3 device description