Parker EME
Setting up Compax3
192-120113 N08 C3I12T11 - December 2010
137
For intra-device inputs I0 .. I3 as well as the outputs O0 ... O3 you can choose
between fixed or free assignment.
With fixed assignment of the intra-device inputs I0 ... I3, the respective functions
can either be triggered via the inputs or via RS232 / RS485
It applies:
The motor is only energized if I0 = "1" AND control word Bit 0 ="1"
Stop is active if, I1 ="0" OR Control word Bit 1 ="0"
and Manual- inputs and control word are OR - linked.
Control word
Structure of the control word (object 1100.3)
Bit
Function
Corresponds
to *
Bit0
Quit (edge) / energize axis
I0: X12/6
Bit1
No Stop
I1: X12/7
Bit2
JOG +
I2: X12/8
Bit3
JOG -
I3: X12/9
Bit4
O0 X12/2
(only if O0...O3
is defined as
freely
assignable)
Bit5
O1 X12/3
Bit6
O2 X12/4
Bit7
O3 X12/5
Bit8
Address 0
Bit9
Address 1
Bit10
Address 2
Bit11
Address 3
Bit12
Address 4
Bit13
Start (edge)
The address of the current motion set is read
in new.
Bit14
No Stop (2nd Stop)
Bit15
Open brake
* does only apply if the respective inputs are assigned fixedly.
Bit0 = least significant Bit