![Parker Compax3 C3I20T11 Скачать руководство пользователя страница 303](http://html1.mh-extra.com/html/parker/compax3-c3i20t11/compax3-c3i20t11_operating-instructions-manual_3811584303.webp)
Parker EME
Communication
192-120103 N13 C3I20T11 / C3I32T11 December 2010
303
5.4
Profibus & Profinet
In this chapter you can read about:
Profibus / Profinet configuration ..................................................................................... 303
Status machine .............................................................................................................. 311
Cyclic process data channel .......................................................................................... 315
Acyclic parameter channel ............................................................................................. 329
Notes on the configuration of the Profibus master
Before configuring the Profibus master (e.g. S7), you will have to configure the
Compax3 axis.
In the
Profibus/Profinet window
(see on page 303) of the configuration wizard
you will receive the status message “Profibus/Profinet Telegram” with the
information on the telegram which can be set in the master/controller (PPO type).
5.4.1.
Profibus / Profinet configuration
In this chapter you can read about:
Operating modes ...........................................................................................................303
Configuration of the process-data channel .....................................................................304
Operating mode: Speed control .....................................................................................305
Operating mode: Direct positioning ................................................................................307
Operating mode: Positioning with set selection ..............................................................309
PKW parameter channel ................................................................................................311
Error Reaction on Bus Failure ........................................................................................311
Following are described the input windows of the Profibus/Profinet configuration
wizard.
Can be called up in the tree (Compax3 ServoManager, left window) under
"configure configuration".
5.4.1.1
Operating modes
The assignment of the process data channel (PZD) depends on the operating
mode.
Make the selection between:
Speed control:
via the PZD the nominal rotation speed is specified and the actual values are
read back.
Direct positioning (Position control):
via the PZD setpoint values (setpoint position, setpoint rotation speed, setpoint
acceleration) are specified and actual values are read back.
Positioning via set selection:
via the PZD sets are selected and started via the set address. The set table is
previously written in with the aid of the C3 ServoManager.