47
Medium Flow Compressed Air Dryers - IOMI.
Display During A Typical Drying Cycle (CDAS HL shown)
VALVE
VALVE STATUS
COLUMN STATUS
ENERGY SAVING
COLUMN
PRESSURISED
Inlet 1
Open
Column 1
On-line
Drying
-
Yes
Exhaust
Open
-
Inlet 2
Closed
Column 2
Off-line
Regenerating
No
No
VALVE
VALVE STATUS
COLUMN STATUS
ENERGY SAVING
COLUMN
PRESSURISED
Inlet 1
Open
Column 1
On-line
Drying
-
Yes
Exhaust
Closed
-
Inlet 2
Closed
Column 2
Off-line
Repressurising
No
Yes
VALVE
VALVE STATUS
COLUMN STATUS
ENERGY SAVING
COLUMN
PRESSURISED
Inlet 1
Open
Column 1
On-line
Drying
-
Yes
Exhaust
Closed
-
Inlet 2
Closed
Column 2
Off-line
ECO
Yes
Yes