3
2 Description
The Parker domnick hunter BAF010 and BAF015 is a two stage point of use breathing air filter, designed to provide high quality breathable air
to meet breathing air standards for compressed air fed respiratory devices. These combine high efficiency coalescing pre-filtration elements
with odour removal, activated carbon elements in a two stage housing. A pressure regulator allows adjustment of line air pressure to usable
levels.
2.1 Technical Specification
Model
Pipe Size
L/s
m
3
/min
m
3
/hr
cfm
Inlet
Outlet
BAF010
¼"
⅜
"
6
0.4
22
13
BAF015
⅜
"
⅜
"
12
0.8
46
27
Filter Grade
Models
Min Operating Pressure
Max Operating Pressure
Max Recommended
Operating Temperature
Min Recommended
Operating Temperature
bar g
psi g
bar g
psi g
BAF
010
4
58
10
145
30°C
86°F
1.5°C
35°F
BAF
015
4
58
10
145
30°C
86°F
1.5°C
35°F
This product will not remove CO, CO2 or toxic gases
BAF-010 = BSPT
BAF-015 = BSPT
BAF-010-NPT = NPT
BAF-015-NPT = NPT
Содержание BAF010
Страница 2: ......
Страница 9: ...7 1 4 M ...
Страница 15: ...13 ...
Страница 21: ...19 1 4 M ...
Страница 27: ...25 ...
Страница 33: ...31 1 4 M ...
Страница 39: ...37 ...
Страница 45: ...43 Nota El indicador de aceite no indica la vida del filtro 1 4 M ...
Страница 51: ...49 ...
Страница 57: ...55 1 4 M ...
Страница 65: ...NOTES ...
Страница 66: ...NOTES ...
Страница 67: ......