Parker BAC-4015 Скачать руководство пользователя страница 13

11

 

Image shows a coalescing filter with an automatic drain

The adsorption fllter is fitted with a manual drain and does not require 
changing.

1

4

4

1

2

2

3

Replacing the Elements

Unscrew the filter bowls (1) and remove the used elements (2). 

Note. We recommend the use of gloves when touching contaminated 
elements.

Unscrew the automatic drain (3) and fit the replacement. Tighten the 
drain to 2.5Nm. 

Replace the O-rings (4) located in the filter head with the new O-rings 
provided.

Insert the new elements into the filter bowls ensuring that the lugs are 
seated correctly in the grooves.

Refit the filter bowls and heads ensuring that the threads are fully 
engaged and the locking details are aligned. 

Note: To ensure that the bowl is fully engaged into the head, the 010-
030 bowl requires 360

o

 of rotation until the thread stop.

Attach the element change date label to the filter bowl and write on the 
date the element is to be replaced. i.e 12 months after element change.

Note. Do not use solvents or alcohol to clean the labels as this could 
cause damage.

Slowly open the upstream valves to pressurise the filter, followed by the 
downstream valves to pressurise the system.

Discard used items in accordance with local regulations.

10 

Repeat these procedures for all filters.

11 

Re pressurise the unit.

Ensure that the filter is isolated from the compressed air 

system and fully depressurised prior to carrying out any 

maintenance procedures which are to be done by qualified, 

trained authorised personnel only.

Ensure to lubricate the O-ring and threads with a suitable 

acid free petroleum jelly.

Do not open the valves rapidly, or subject the filter to 

excessive pressure differential, as damage may occur.

Содержание BAC-4015

Страница 1: ...Breathing Air Purifier BAC 4015 Original Language User Guide aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing shielding EN...

Страница 2: ......

Страница 3: ...acking the Equipment 4 2 3 2 Lifting and handling 4 2 4 Overview of the Equipment 5 3 Connecting and Operating the Equipment 6 3 1 General Installation Requirements 6 3 2 Operating the Equipment 6 3 3...

Страница 4: ...very nature used in critical applications It is therefore essential that only competent personnel trained qualified and approved by Parker Hannifin should perform installation commissioning service a...

Страница 5: ...atalyst stage The desiccant purifier maintains a low dewpoint by utilising the heatless pressure swing adsorption principle Cycle time is controlled by a pneumatic cam timer 4th Stage Grade HC catalyt...

Страница 6: ...inform the delivery company immediately and contact your local Parker domnick hunter office 2 3 1 Unpacking the Equipment The panels of the crate are secured using nails Starting with the top carefull...

Страница 7: ...or c w keys 8 G 3 8 Regulator 2 Inlet adaptor 9 Hours Run Meter 3 Outlet manifold 10 Inlet pressure gauge 4 AC Grade filter 11 Outlet pressure gauge 5 HC Grade filter 12 Audible warning device 6 AIR P...

Страница 8: ...be taken to ensure that the compressor is operating efficiently and not overheating Care should also be taken in the location of the compressor intake to ensure that no harmful contaminants are drawn...

Страница 9: ...or 3 3 3 Hours run meter The meter gives a visual indication of the operating hours of the BAC 4015 When pressure to the purifier is established an internal pressure switch closes operating the meter...

Страница 10: ...e Oil vapour content increases exponentially to inlet temperature reducing element life Additionally as temperature increases the adsorption capacity decreases again reducing element life Relative Hum...

Страница 11: ...Valve Kit Catalogue No 608233680 Description Catalogue No Contents Order Qty 015AC 015AC AC cartridge 1 015HC 015HC HC cartridge 1 Note One kit is required for each dryer Description Catalogue No Con...

Страница 12: ...scription Catalogue Number Contents Kit Control Valve DM012 080 608233680 Pilot Valves Fixing screws Control Valve Kit Note Ensure that the dryer is filled using a Snowstorm filler and replace the col...

Страница 13: ...the head the 010 030 bowl requires 360o of rotation until the thread stop 7 Attach the element change date label to the filter bowl and write on the date the element is to be replaced i e 12 months a...

Страница 14: ...ervice are extremely accurate and produce invaluable information Importantly Parker informed recommendations lead to significant savings for our customers which mean they return time and time again fo...

Страница 15: ...Route N A EC Type examination Certificate Notified body for PED N A Authorised Representative Derek Bankier Divisional Quality Manager Parker Hannifin Manufacturing Limited dhFNS Declaration I declare...

Страница 16: ...NOTES...

Страница 17: ...NOTES...

Страница 18: ...NOTES...

Страница 19: ......

Страница 20: ...Budapest Tel 36 1 220 4155 parker hungary parker com IE Ireland Dublin Tel 353 0 1 466 6370 parker ireland parker com IN India Mumbai Tel 91 22 6513 7081 85 IT Italy Corsico MI Tel 39 02 45 19 21 park...

Отзывы: