Parker Aries AR-01xR Скачать руководство пользователя страница 2

AR-01xR to AR-13xR

Servo Drives w/

Step and Direction

ries

RS-232/485 Configuration

Output Power Connector

Website

Mains Power Connector

Drive I/O Connector

Motor Feedback Connector

NOTE: A box surrounding the pins indicates a requirement for twisted pair wiring.

The 26-pin DRIVE I/O connector (female D-subminiature) also functions as the 

communications (COM) port.

Warning!

You must connect the drive’s protective conductor terminal, marked with the earth symbol 

, to a reliable system Protective Earth.

The drive’s connector strip terminals are at hazardous voltages when power is applied to 

the drive, and up to several minutes after power is removed. Lower voltages may still be 

present for several minutes after power is removed.
During normal operation, these high voltage terminals must not be accessible to the user.

2

1

3

4

5

6

7

8

9

12

11

13

14

15

16

17

18

22

21

23

24

25

26

10

20

19

Rx

Tx

Gnd

Drive I/O Connector

configuration for RS-232 

+

-

Gnd

Drive I/O Connector

configuration for RS-485

2

1

3

4

5

6

7

8

9

12

11

13

14

15

16

17

18

22

21

23

24

25

26

10

20

19

(Talk)

   

1

ENABLE–   

21

DGND 

 

2

ENC A+   

3

ENC A–   

4

ENC B+   

5

ENC B–   

6

ENC Z+   

7

ENC Z–   

8

FAULT+   

9

FAULT–   

16

STEP+ 

 

10

STEP– 

 

11

DI 

12

DIRECTION– 

13

AIN+ 

 

14

AIN– 

 

15

DGND 

 

17

RESET+   

18

RESET–   

23

DGND 

 

19

DGND 

 

20

DGND 

 

22

DGND 

 

24

RS-232Rx/RS-485+  25
RS-232Tx/RS-485–  26

Signal

Pin

No Connection 

1

No Connection 

2

Thermal–   

3

Re 

4

Reference-  

15

No Connection 

5

Thermal-   

6

   

10

SIN– 

 

7

SIN+ 

 

8

No Connection 

9

COS– 

 

11

COS+ 

 

12

No Connection 

13

No Connection 

14

Signal

Pin

http://www.parkermotion.com

UL Standard of Compliance

Fuse Information

Aries has no internal fuses. For safety, you must

provide a fuse in each of the AC input lines.

See Fuse Information in the Aries Hardware

Installation Guide (included on the Aries CD).

508c

MOT

OR FEEDBACK

DRIVE I/O

ARIES

MOTOR

U
V

W

BK

BK

R+

R-
C2
C1

L2
L1

R+

R-

C2
C1

L2
L1

Protective Earth GND

Control Input Power

Control Input Power

External Regeneration Resistor
External Regeneration Resistor

Motor Input Power

Motor Input Power

MOTOR

BK

BK

W

V

U

Motor Brake Relay

Motor Brake Relay

Motor Safety Earth

Motor Phase

Motor Phase

Motor Phase

Factory installed jumpers

   C1 to L1

   C2 to L2
Remove jumpers to use 

separate control and motor 

mains AC power input.

!

!

Drive LED Status Indicators

Off
Green
Yellow
Off
Yellow
Off
Yellow (flash)
Yellow
Yellow & 1 Green (flash)
Yellow & 2 Green (flash)
Yellow & 3 Green (flash)
Yellow & 4 Green (flash)

Green
Yellow/Green (alternating)
Green
Red
Off
Red (flash)
Red (flash)
Red
Red
Red
Red
Red

Power on, enabled
Autorun mode
Power on, regeneration active
Power on, disabled–No Fault
Power on, boot process
Waiting for OS download
OS download in process
Control power mode active
Bridge Fault
Feedback Fault
Thermal Fault
Other Fault

LED–Left

LED–Right

Drive Status–What it means

Motor Input Power

120/240 VAC, 50/60 Hz, Single phase

*  When using the SinCos 

protocol, pins 9 and 13 

require twisted pair wiring.