ACR8010 Hardware Manual
P/N PM08121
32
ACR8010 MOTHERBOARD HARDWARE WIRING
Encoder Inputs (P1), Continued
The ACR8010 can accept any feedback device that supplies either a +5V or +12V
differential signal to the ACR8010. The most common type of device is a differential
encoder. Refer to the table below for common encoder setups.
Encoder Type
ACR8010 Pull-
up/Jumper Setting
Length of Cable/Type
Differential Line Driver
(+5 Volt Outputs)
Remove Pull-ups
100 ft. (Beldon 9330 Shielded Twisted Pair)
Open Collector Driver
(No Pull-ups on Encoder)
Install Pull-ups and
Jumper to +12V
75 ft. (Beldon 9330 Shielded Twisted Pair)
Open Collector Driver
(With Pull-ups to +5 V on Encoder)
Install Pull-ups and
Jumper to +5V
50 ft. (Beldon 9330 Shielded Twisted Pair)
TTL Driver
(+5 Volt Outputs)
Remove Pull-ups
50 ft. (Beldon 9330 Shielded Twisted Pair)
When using a single-ended encoder (an encoder without the A-, B-, or Z- outputs),
additional pull-ups and pull-down resistors must be added externally to the ACR8010
board in order for the ACR8010 to read the encoder signals. Warning: This is not a
recommended mode of operation. Noise immunity is significantly reduced.
Refer to the ACR8010 Typical Connection Diagram section of this manual for details on
wiring a single-sided encoder to the ACR8010.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com