Parker A4AL-DN Скачать руководство пользователя страница 8

Refrigerating Specialties Division

8

Parker Hannifin Corporation • Refrigerating Specialties Division
2445 South 25th Avenue • Broadview, IL 60155-3891
Telephone (708) 681-6300 • Fax (708) 681-6306

Warranty

All Refrigerating Specialties products are warranted
against defects in workmanship and materials for a
period of one year from date of shipment from
originating factory.  This warranty is in force only
when products are properly installed, field as-
sembled, maintained, and operated in use and ser-
vice as specifically stated in Refrigerating Special-
ties Catalogs or Bulletins for normal refrigeration
applications, unless otherwise approved in writing
by Refrigerating Specialties Company.  Defective
products, or parts thereof returned to the factory
with transportation charges prepaid and found to be
defective by factory inspection will be replaced or
repaired at Refrigerating Specialties option, free of
charge F.O.B. factory.  Warranty does not cover
products which have been altered, or repaired in the

field; damaged in transit, accidents, misuse, or
abuse.  Products disabled by dirt or other foreign
substances will not be considered defective.

The express warranty above constitutes the only
warranty of Refrigerating Specialties products, and
is in lieu of all other warranties, expressed or implied,
written or oral, including any warranty of merchant-
ability or warranty of fitness for a particular purpose
and in no event is Refrigerating Specialties respon-
sible for any consequential damages of any nature
whatsoever.  No employee, agent, dealer or other
person is authorized to give any warranties on
behalf of Refrigerating Specialties nor to assume for
Refrigerating Specialties any other liability in con-
nection with any of it products.

SYMPTOM

PROBABLE REASON

CORRECTION

Regulator does not 
shut off flow

Diaphragm or seat dirty, damaged or 
frozen

Clean or replace. Clean strainer

Diaphragm follower stuck or damaged Clean or replace. Install follower 

carefully

Piston jammed with excess dirt

Remove and polish piston and bore 
with crocus cloth. Clean valve and 
strainer

Modulating plug leaking due to excess 
dirt or damaged

Clean or replace.  If used on liquid, 
check for erosion due to excessive 
flash gas by subcooling or by reducing 
pressure drop across valve by providing 
restriction at valve outlet.

Regulator does not 
open

Pressure Regulator Diaphragm 
ruptured or badly deformed

Replace. Make sure 2 diaphragms are 
installed.

Diaphragm follower stuck, damaged or 
frozen

Clean or replace. Install follower 
carefully

Piston worn, too much clearance

Replace piston. Check for reason.  If 
used or liquid, check for flash gas.

Regulator Operation 
erratic

Diaphragm or seat dirty, damaged.

Clean or replace. Clean strainer

Diaphragm follower has dirt on the 
outside diameter or outside diameter is 
damaged.

Clean or replace

Regulator too far oversized.

Check load.  Replace with smaller 
regulator or investigate use of Reduced 
Capacity Plug Kit.

Pressure drop across 
regulator too high

Inlet or outlet restricted

Check for restriction.  Clean strainer.

Regulator too small

Replace with proper size regulator

Large amount of flash gas in liquid line Reduce flash gas by subcooling. 

Reduce line restriction by increasing 
line size, particularly at the regulator 
outlet.  Replace with larger regulator.

High pressure drop causes high rate of 
expansion of gas at regulator outlet

Increase pipe size at the outlet of the 
regulator

Regulator does not open all the way.

Check piston for wear. Replace, if 
needed.

Содержание A4AL-DN

Страница 1: ...s All A4AL Regulators are pilot operated using upstream pressure for the opening force and require a minimum 2 psi 0 14 bar pressure drop to fully open These valves are generally ordered with close co...

Страница 2: ...r the system has been in operation for a while and make any minor corrections neces sary Installation All regulators are packed for maximum protec tion Unpack carefully check the carton to make sure a...

Страница 3: ...l the flats onthestembarelyprotrudefromthestuffingbox nut Push Piston 30 down against the spring force The piston should move freely down and be returned by the spring force If the piston is jammed or...

Страница 4: ...g must be replaced Check other system components for proper op eration Check hand valves in the system to make sure they are open or closed as required and the system is receiving liquid or gas as the...

Страница 5: ...Spring Rest Lower 15 Diaphragm Follower 16 Gasket Bonnet 17 Diaphragm 18 Seat Pilot 19 Gasket Adapter 20 Flg Ring tube Asm 27 Gauge Port Pipe Plug 28 Adapter Body 29 Gasket Body 30 Piston Stem 31 Scre...

Страница 6: ...BOTTOM A4A S4A 1 5 8 to 2 1 2 DUCTILE IRON GGG 40 3 BONNET A4W DUCTILE IRON GGG 40 3 COMPONENT DESCRIPTION MATERIAL Kv VOLUME BODY 2 A4A DN DUCTILE IRON GGG 40 3 42 4 1 61 L ADAPTER 2 A4A DN DUCTILE...

Страница 7: ...A43P 414 16 3 432 17 0 485 19 1 505 19 9 620 24 4 676 26 6 C 164 6 2 203 8 0 251 9 9 252 9 9 311 12 2 359 14 1 G A4P A4L 244 9 6 248 9 8 287 11 3 302 11 9 324 12 8 361 14 2 A43P 266 10 5 270 10 7 308...

Страница 8: ...me for Refrigerating Specialties any other liability in con nection with any of it products SYMPTOM PROBABLE REASON CORRECTION Regulator does not shut off flow Diaphragm or seat dirty damaged or froze...

Отзывы: