Parker 700-00027-0 Скачать руководство пользователя страница 2

2

700-00027-0, DFC-3 Plug Top Driver Unit.

P

arker

D

enison Have Long Recognised the Need for Driver Electronics Which Are Reasonably Priced,  

Easy to Apply,  Mechanically Sound and Can Be Utilised in Many Differing Environments and With a 
Wide Range of Proportional Products. 

T

he Ideal Is to Keep Product Variation to a Minimum Which Will Reduce Spares Stocking As Well As 

Allowing Commissioning Engineers, System Designers and Machine Operators to Become Familiar With 
a Limited Range of Connections and Adjustments Which Will Improve Overall Efficiency, Confidence in 
the Electronic and Hydraulic Components and Once Comfortable With the Operation and Parameters, 
Will Generate Proven Electro-Hydraulic ‘Building-Blocks’ Which Can Be Used Time and Time Again 
Without Extra Design or Production Time Being Wasted on Learning a New Product.

T

his industry and application unique ‘Plug Top Controller’ is specifically designed for 

direct connection to 

any engine Control Unit ( ECU )

having a proportional Pulse Width Modulated ( PWM ) output for fan 

speed control and can be used to directly drive 24V coiled valves requiring upto 600mA drive current.

The 700-00027-0 uses the latest internal component and circuit design technology to give

full CE 

compliance 

to present 

EMC

directives to ensure maximum operational potential and efficiency, while 

offering a full IP68 ( NEMA 6P ) rating in 

ONE

unique and easy to apply package.

T

his versatile controller has been designed to allow users access to an extremely cost effective driver 

device while ensuring that the valve product is controlled to the best possible characteristic.

T

he small size and NEMA 6P / IP68 rating of this unit allows internal OR external applications to be 

approached with confidence that some other drivers of this type cannot allow.

T

he following ‘Application Hints’ for this versatile driver unit are only issued as a guide and if required, 

further help and /or advice should be sought from your Local distributor or from Parker Denison internal 
sales departments.

T

o keep pace with the changing laws on environmental issues, new legislation regarding engine 

efficiency while also reducing machine operating costs, the award winning ‘Parker Denison Fan 
Controller’ ( DFC )  systems program has now produced a third iteration of the controller ( DFC-3 ) aimed 
specifically at on-road, small size, uni-directional, simple cooling systems. By using this 700-00027-0 
controller plug and for example, the M5AF the vane motor with integral valving, the cooling system 
becomes a two part system where the fan speed is directly controlled by the Engine Control Unit ( ECU ) 
PWM output.

T

he ECU, PWM output typically operates from 10% to 90% pulse width based on a 5V -28V maximum 

system voltage. The PWM frequency can vary from different manufacturers and the 700-00027-0 can 
accept frequencies of 20Hz without any adjustment required by the operator.

This ‘Plug Top Driver’ has been designed to interface and operate with:-
Engine OEM Engine Control Unit ( ECU ) PWM outputs from 5-28V at 20Hz 
HydraCool™ Fan system pressure control manifold blocks.
Vane and gear motors with integral pressure control valve.
Electrical pressure compensation options on Piston pumps.
Systems with 24V cartridge valves as fluid controlling elements Positive or Negative logic ).

Fan systems requiring direct connection to the Engine Control Unit ( ECU ).

• Parker Denison Award winning ‘HydraCool™’ fan systems.
• With Vane or gear motors for 2 part cooling system.
• ANY Single coil proportional pressure , flow or screw-in cartridge control valves. 
• Variable piston pump electro-hydraulic stroker coil.
• Mobile applications where ‘CHASSIS’ or ‘EXTERNALLY’ mounted.
• Exposed , ‘Outside’ or harsh environment applications.
• High Vibration and /or ‘G’ force applications.
• High Humidity applications.
• Marine usage.
• System load / Unload valves.
• Pump stroker ( single side operation )
• Applications where ‘Damage’ may occur to exposed electronic components.

Application Areas:

Product Compatibility:

Introduction:

Information:

For more information or comments, e-mail on: 

[email protected]

Содержание 700-00027-0

Страница 1: ...1 Fan Controller Unit 700 00027 0 Application and Information Manual DFC 3 24V 600mA Direct Connect option for 20Hz ECM output Publ 700 00027 0 July 2005 ...

Страница 2: ... advice should be sought from your Local distributor or from Parker Denison internal sales departments To keep pace with the changing laws on environmental issues new legislation regarding engine efficiency while also reducing machine operating costs the award winning Parker Denison Fan Controller DFC systems program has now produced a third iteration of the controller DFC 3 aimed specifically at ...

Страница 3: ...low wires TO or FROM the unit to short circuit to each other or chassis cabinet e t c 8 Attempt to use this unit in areas of intense RF without adequate screening measures 8 Disconnect or connect wires to or from this unit unless it it isolated from the power supply 8 Use this unit in temperatures that exceed those specified as operation may be effected Important Notes 700 00027 0 DFC 3 Plug Top D...

Страница 4: ...llow Default to full fan speed safety operation if the power supply to the DFC 3 controller is removed Adjustment Guide NON NON Inverting Inverting valve control operation valve control operation Typical characteristic of a normal pressure or flow control valve or variable piston pump Electro hydraulic stroker This option WILL NOT allow Default to full fan speed operation if the power supply to th...

Страница 5: ...0 60 70 80 100 10 90 Adjustment Guide Controller Input Output Logic Controller Input Output Logic see page 6 7 8 for details see page 6 7 8 for details PWM input NOTE For operational safety if the input PWM signal is below approx 5 the output to the valve is OFF 0 20 40 60 80 100 110 Output Current mA 0 20 30 40 50 60 70 80 100 PWM input 10 90 I Max 100 I Max 75 I Max 50 90 PWM 5 PWM 0 PWM 100 PWM...

Страница 6: ...output Variable from 100Hz to 250Hz 20 11 Environmental Totally ENCAPSULATED Printed Circuit Board 12 IP Rating IP68 Min When assembled correctly 13 NEMA Rating NEMA 6P 14 Humidity 95 Non Condensing 15 Storage temp 120 Deg C 250 F Max 16 Working temp 40 Deg C 40 F Max 70 Deg C 160 F Max Inc Ambient DFC 3 Specifications TOP VIEW OF PLUG DRIVER WITH LID REMOVED Output Current Adjustment I Max Clockw...

Страница 7: ...e opaque lid carefully ensuring that seal is maintained Replace securing screw and tighten Do not overtighten or lid damage is seen Unit is now ready for continuous application use Adjust Dither frequency to suit valve product being driven Fully Anti clockwise approx 100Hz Fully Clockwise Approx 250Hz Suggested setting is MID position Set command to minimum PWM Isolate plug from 24VDC supply 700 0...

Страница 8: ... seal is maintained Replace securing screw and tighten Do not overtighten or lid damage is seen Unit is now ready for continuous application use Adjust Dither frequency to suit valve product being driven Fully Anti clockwise approx 100Hz Fully Clockwise Approx 250Hz Suggested setting is MID position Set command to minimum PWM Isolate plug from 24VDC supply 700 00027 0 DFC 3 Plug Top Driver Unit Ne...

Страница 9: ...TE The Emergency Fan MINIMUM SPEED configuration shown above assumes that the controller is being used with an inverting operation pressure valve and the PWM input is positive logic i e 0 PWM fan full on 100 PWM fan full off Closing the relay will force the input to 24V supply voltage and the fan will be controlled to fully OFF the fan may still rotate even in this state if absolute zero fan speed...

Страница 10: ...mm All Internal Dividers Lid material High Impact Resistant Molded ABS Lid Colour Opaque clear Lid finish Matt Unit size See above size detail drawings Unit Weight Approx 400 grams including Encapsulation material Cable Wire entry Via PG11 gland to fixed cable Encapsulation Flame Resistant Black Two Part Epoxy Resin Wire length Approx 3 Metres colour coded cable Wire specification 4 core 16 02 wit...

Страница 11: ...een valve coil and driver plug For high moisture applications apply lithium grease between valve coil and driver plug base before final assembly and mounting screw tightening process For total immersion applications follow above step and additionally fill driver plug lid with lithium grease after adjustment and before final assembly to form liquid proof seal around all potentiometers and units plu...

Страница 12: ...12 NOTES Visit us on the web at www parker com hydraulics fandrives ...

Отзывы: