Appendix B
-
Internal Protection
Product Rating
All standard configurations will pass IP20 specifications with the following exception:
The cable carrier is not covered by the specification.
All standard configurations, (less cable carrier), can be configured to pass IP30
specifications by utilizing the
“
IP ship kit
”
supplied with each unit as follows:
1.
Using the supplied
Foil Discs
, cover all
counter
-
bored base mounting holes
that are not covered by
your mounting surface.
2.
Using the supplied M6
set screws
, plug all unused
carriage mounting holes
that are not covered by
the load or load plate. Note: Only insert the set screws until they are flush or slightly recessed from
the mounting surface. If they are inserted too deeply they will make contact with the extrusion or
center cover and may cause failure.
3.
Using the supplied M6
set screws
, plug all
threaded base mounting holes
that are not covered by
your mounting surface. Depending on the travel length, some set screws will not be used.
4.
Using the supplied M4
set screws
, plug the
exposed threaded holes on both end blocks
of the unit
(3 holes per end block). A few drops of Loctite® should be applied to the threads prior to insertion
to ensure they do not come loose during normal operation.
5.
Using the supplied plastic plugs plug the Vent/Air purge holes in each end block.
Содержание 406LXR Series
Страница 30: ...26 ...
Страница 38: ...34 ...
Страница 64: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Страница 65: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Страница 66: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Страница 67: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Страница 68: ......