Chapter 8
Operation and Simple Running
This chapter defines and explains the terms and names describing the control, running and
status of the inverter. Please read it carefully as it will ensure correct operation.
8.1 Basic Conception
Control Mode
AC10 inverter has the following control modes: sensorless vector control (F106=0), V/HZ
control (F106=2) and vector control 1 (F106=3).
Mode of Torque Compensation
Under V/HZ control mode, AC10 inverter has four kinds of torque compensation modes:
Linear compensation (F137=0);
Square compensation (F137=1);
User-defined multipoint compensation (F137=2);
Auto torque compensation (F137=3)
Mode of frequency setting
Please refer to F203~F207 for the method for setting the running frequency of the AC10
inverter.
Mode of controlling for running command
The channel for inverter to receive control commands (including start, stop and jogging, etc)
contains 5 modes:
0. Keypad control;
1. Terminal control;
2. Terminal control
3. Modbus control;
4. TeModbus
The modes of control command can be selected through the function codes F200 and F201.
Operating status of inverter
When the inverter is powered on, it will have one of four types of operating status:
Stopped status
Programming status
Running status
Fault alarm status
They are described in the following:
Stopped status
If the inverter is re-energised (if “auto-startup after being powered on” is not set) or decelerate
the inverter to stop, the inverter is at the stopped status until receiving control command. At
this point, the running status indicator on the keypad goes off and the display shows the
display status before power down.
Programming status
Through keypad panel, the inverter can be switched to the status that can read or change the
function code parameters. Such a status is the programming status.
There are numbers of function parameters in the inverter. By changing these parameters, the
user can realize different control modes.
Running status
The inverter at the stopped status or fault-free status will enter running status after having
received a start command.
The running indicator on keypad panel lights up under normal running status.
Содержание 10G-46-0600-BF
Страница 2: ......
Страница 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Страница 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Страница 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Страница 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Страница 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Страница 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Страница 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...