Parker Research Corp B300-MR Series Скачать руководство пользователя страница 2

GENERAL SAFETY RULES 
 

Please read all instructions. Failure to follow all instructions listed below may result in injury. If the 
equipment is used in a manner other than as specified in these operating instructions, the protection 
provided by the equipment may be impaired. Always wear eye protection. 

 
DO NOT OPERATE 

unit from a DC power source.

 

 
Do not abuse the power cords. Never carry the instrument by the cord or attempt to unplug the 
instrument using the cord. Always operate the instrument with the standard installed cord. Changing or 
using a damaged cord can increase the risk of electrical shock. The cord should be checked 
periodically for any damage. 
 
Do not position the instrument such that it would be difficult to operate the disconnect device (plug) on 
the end of the power cord. 
 
The outside housing should remain intact and solid. Any damage, chipping, or separating exposing 
internal wires is a hazard. Instruments should not be used in this condition. The outside housing should 
be periodically checked for damage. 
 

Duty Cycle: 

The B300-MR series is designed for a 50% duty cycle. This instrument is equipped with an 

internal thermal switch that will shut down the device if overheated. The instrument will automatically 
reset itself when the temperature drops. Continuous operation may cause overheating and damage the 
Contour Probe. 
 

Operating Environment: 

Temperature: 32° to 104°F (0° to 40°C). Relative humidity: 10% to 95%, non-

condensing 
 

Shipping and Storage Environment: 

Temperature: 40° to 140°F (4.44° to 60°C). Relative humidity: 

5% to 95%. Vibration and shock: As encountered in normal shipping and handling with no degradation. 
 

General Cleaning 

The outside surface of the instrument can be periodically wiped clean with a clean cloth and a mild 
general purpose cleaner. Avoid using cleaners such as lacquer thinner, or mineral spirits that could 
damage the outside housing. 
 
Never attempt field service. All 300 series Contour Probes should be returned to the factory for repairs. 

 
OPERATION: 

Connect the instrument plug into a grounded power outlet of proper voltage. Place the 

Contour Probe legs upon the work surface with the suspected defect at right angles to the legs (good 
contact will produce the best results). Push the test switch to energize the instrument. Lightly dust or 
float dry magnetic inspection powder over the area being inspected. Defect indications will be revealed 
in a direction shown on figure 2. Turn the Probe 90 degrees from the first test and repeat the process. 
This method may also be utilized when applying a wet medium. Check all procedures and standards for 
further details involving inspection specifics. 
 

Do not position the instrument housing against ferrous materials while energizing. The 
internal magnetic field created during such positioning could damage the circuitry and 
effect instrument performance

 
 
 

 
 

 

CORRECT 

 

 

 

 

  INCORRECT 