1.  This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure 

     must be capable of supporting 300 lb. load on fountain.

2.  Refer to rough-in for plumbing.

3.  Install shut-off valve on water supply. (Valve not furnished)

4.  Locate and install fountain using 3/8" minimum fasteners, (Fasteners not furnished).

5.  Prior to installing the bottle filler to the arm mount of the fountain, insert the drain tube (Item #6) into the arm tunnel and 

     adjust drain to lean to the left side of arm when facing button.  Install bottle filler to arm being sure drain tube is above  

     mounting plate of filler. Install mounting hardware to secure filler to fountain.

6.  Connect water supply and fountain drain. Connect Bottle Filler water line to regulator with the supplied 3/8" to 1/4" reducing 

     fitting. Water connection and drain must comply with local codes.

7.  Turn on water supply and check all connections for leaks.

CAUTION:

 This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the   

                   inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line pressures 

                   lower than 20 PSI or higher than 105 PSI is not covered by warranty.

  8. Water supply 3/8" O.D. unplated copper  tube. Waste 1-1/4" IPS. Contractor to supply waste trap and service stop valve in

       accordance with local code.

  9. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being  

      connected  to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color, 

      or sediment problems.

10. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and 

      the fountain. Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a    

 

positive stop, approximately 3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO PLASTIC FITTINGS AS    

 

DAMAGE TO THE O-RINGS MAY RESULT.

INSTALLATION INSTRUCTIONS

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES 

IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE 

BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN 

ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE 

WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN 

FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE 

FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

                     TROUBLE SHOOTING AND MAINTENANCE

         

ACTUATION OF QUICK CONNECT WATER FITTINGS:

Fountain is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve 

water pressure, push in on the gray collar while pulling on the tubing. (see Fig.2) To insert tubing, push tube straight into 

fitting until it reaches a positive stop, approximately 3/4".

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

1/4” O.D. TUBE 

WATER INLET 

TO COOLER

3/8” O.D. TUBE CONNECT 

COLD WATER SUPPLY

BUILDING WATER 

INLET

NOTE: WATERFLOW 

DIRECTION

SERVICE STOP 

(NOT FURNISHED)

FIG 1

FIG 2