background image

28

5

output  signal  to  a  speaker  system.  To  prevent  any  DC  damage  to  speaker  systems,  the
amplifier  incorporates  the triak  protection  system  for  each  channel, which  short-circuits  the
amplifier  output  in  case  of  DC  voltage  or  powerful  LF  fluctuations.

High  Frequency  Energy  Protection

In case of any powerful high frequency fluctuations caused by bad contact in the input

cable  connectors  or  those  transmitted  to  the  amplifier  input  from  any  other  device  (e.g.
crossover, mixing console, etc.), the protection system enables the built-in  clip-limiter, which
reduces  the level  of the  input signal.  This  protection system  serves to  prevent any  damage
to tweeters as might be caused by non-musical signals of powerful high frequency spectrum.

Thermal  Protection

The  thermal  protection  is  to  preclude  any  overheating  of  the  output  stage.
The  amplifier  incorporates  a  double-step  thermal  protection  system  which  precludes

overheating  of  the  output  stage  of  the  amplifier  without  suspending  its  operation  and
disabling  the  input  signal  (and  output  signal,  accordingly).

The  thermal  protection  system  is  coordinated  with  the  cooling  system  and  in  the

following  way.

When the output power is fairly low, the fan runs at a low speed. As the output power

goes  up  and  so  rises  the  temperature  of  the  output  transistors,  the  fans  gradually  gain
speed.

Whenever the  output stage  temperature reaches  85

°

Ñ

, the thermal protection system

disables  the upper  voltage  of the  output  stage,  thus significantly  reducing  the output  power
of  the  respective  channel.  This  status  is  indicated  by  a  slightly  (half-)  lit  ALARM  LED.  The
adequate  sound  quality  in  this  case  is  provided  by  the  built-in  optoelectronic  Clip-limiter
which  reduces  the  input  signal  level,  should  any  distortion  occur.

If overheating of the output stage persists and its temperature rises to 95

°

Ñ

 (as a rule,

this is the case only when the cooling fan has broken down), the thermal protection system
inhibits the input signal as well as the output stage of the respective channel. This status is
indicated  by  a  brightly  (full-)  lit  ALARM  LED.  The  amplifier  automatically  resumes  its
operation,  in  the  reverse  order,  after  the  output  stage  transistors  have  cooled  down.

Soft  Start

The  soft  start  system  is  provided  to  reduce  inrush  current  to  the  amplifier  and  to

minimize  the  noise  contributed  by  the  amplifier  to  the  power  mains  during  the  power-on
process.

Soft  Signal  Start

During  the  power-on  process,  this  feature  ensures  smooth  gain  from  zero  to  the

maximum level to provide for a smooth rise of the sound level emitted from the loudspeakers.

Balanced  Inputs

The  use  of  balanced  inputs  provides  for  an  essential  reduction  of  the  environment-

induced  hum  and  noise  interference  with  long  input  connecting  cables.

Input  Level  Attenuators

Located  on  the  front  panel,  these  allow  setting  the  amplifier  to  the  required  sensitivity

(each  channel  individually)  which  is  very  helpful  when  several  amplifiers  run  in  parallel,
especially  when  they  drive  different  types  of  speaker  systems  or  are  used  within  multi-
speaker  sound  reinforcement  systems.

Output Power:

 V4-900

MkIII

450W

 

(channel,  4Ohm,  230V)

280W

 

(channel, 8Ohm, 230V)

900W

 

(bridge,  8Ohm,  230V)

 V4-1200

MkIII

600W

 

(channel,  4Ohm,  230V)

330W

 

(channel, 8Ohm, 230 V)

1200W

 

(bridge, 8Ohm, 230V)

 V4-1800

MkIII

900W

 

(channel,  4Ohm,  230V)

500W

 

(channel, 8Ohm, 230V)

1450W

 (bridge, 8Ohm, 230V)

 V2-2400

MkIII

1200W

 

(channel,  2Ohm,  230V)

700W

 

(channel, 4Ohm, 230V)

380W

 

(channel, 8Ohm, 230V)

2000W

 

(bridge, 4Ohm, 230V)

1400 W

 

(bridge, 8Ohm, 230V)

 V4-2400

MkIII

1200W

 

(channel,  4Ohm,  230V)

700W

 

(channel, 8Ohm, 230V)

2000W

 

(bridge, 8Ohm, 230V)

Peak Output Power:

 V4-900

MkIII

700W

 

(channel,  4Ohm,  10ms,  230V)

350W

 

(channel,  8Ohm,  10ms,  230V)

1400W

  (bridge,  8Ohm,  10ms,  230V)

 V4-1200

MkIII

900W

 

(channel,  4Ohm,  10ms,  230V)

450W

 

(channel, 8 Ohm, 10 ms, 230V)

1800W

 

(bridge, 8Ohm, 10 ms, 230V)

 V4-1800

MkIII

1250W

 

(channel,  4Ohm,  10 ms,  230 V)

625W

 

(channel, 8Ohm, 10ms, 230V)

2500W

 

(bridge, 8Ohm, 10ms, 230V)

 V2-2400

MkIII

1800W

 

(channel,  2Ohm,  10ms,  230V)

900W

 

(channel, 4Ohm, 10ms, 230V)

450W

 

(channel, 8Ohm, 10ms, 230V)

3600W

 

(bridge, 4Ohm, 10ms, 230V)

1800W

 

(bridge, 8Ohm, 10ms, 230V)

  V4-2400

MkIII

1700W

 

(channel,  4Ohm,  10ms,  230V)

850W

 

(channel, 8Ohm, 10ms, 230V)

3400W

 

(bridge, 8Ohm, 10ms, 230V)

SPECIFICATIONS

  2-conductor

Содержание V2-2400 MkIII

Страница 1: ...IO II Ltd Vinnitsa Ukraine www parkaudio2 com e mail park parkaudio2 com PROFESSIONAL POWER AMPLIFIERS V series V4 900 V4 1200 V4 1800 V4 2400 V2 2400 MkIII MkIII MkIII MkIII MkIII OWNER S MANUAL PARK AUDIO II ...

Страница 2: ...ACCESSORIES 1 Power Cord 1 ea 2 Owner s Manual 1 ea 3 Warranty 1 ea Printed in Ukraine ...

Страница 3: ... Panel 11 Rear Panel 12 Input Module with Sensitivity Switch 13 Input Module with Crossover 14 Cabel Requirements 15 Input and Output Connectors 16 Rack Mounting Requirements 17 AC Power Requirements 17 Operating Modes 18 LinkingUp 21 Troubleshooting 27 Specifications 28 Operating Conditions 30 Dimensions 31 ...

Страница 4: ...plifier can yield dangerous output voltage Do not touch the non insulated cable parts connected to outputs of the unit in operation CAUTION The amplifier yields high output power The manufacturer shall not be held responsible for any damage to the speakers caused by excessive power from the unit CAUTION Thehigh sound pressurecaused bythe high output signal applied to speaker systems may endanger y...

Страница 5: ...ly in the schematics elements output power and weight Unless specified otherwise the word amplifier hereinafter applies to any of the above models UNPACKING The manufacturer s quality control system provides for careful examination of each product before it leaves the factory to ensure its flawless appearance After unpacking please check the unit for any physical damage In case of damage please co...

Страница 6: ...ty even under overload In case of a short time overload lasting up to 3 msec e g overload caused by a sudden drop of total load impedance only the output stage current protection goes active limiting the current running through the output transistors at the safe level In this case the protection system does not preclude the amplifier from delivering for a short while a full output power without an...

Страница 7: ...the output stage of the respective channel This status is indicated by a brightly full lit ALARM LED The amplifier automatically resumes its operation in the reverse order after the output stage transistors have cooled down Soft Start The soft start system is provided to reduce inrush current to the amplifier and to minimize the noise contributed by the amplifier to the power mains during the powe...

Страница 8: ...s input module Input Filter only for input modules with a sensitivity switch or with a crossover To improve the performance of speaker systems the amplifier incorporates a switch selectable high pass 4 th order filter with a 24dB per octave slope rate This is the filter recommended by all major speaker systems manufacturers This filter cuts off any signals below 35Hz which generally cannot be repr...

Страница 9: ... channels drive two separate loads from two separate signal sources MONO two channels drive two separate loads from a single input signal source BRIDGE two channels drive the same load from a single signal source The operating modes can be selected with the slide switch located on the rear panel Ground Lift This slide switch is used to decouple the signal ground and the chassis ground in order to ...

Страница 10: ...2 Amplifier 1 CHANNEL2 SWITCHED OUTPUT HI position CROSSOVER LO position CHANNEL1 SWITCHED OUTPUT HI position CROSSOVER LO position AMPLIFIER BLOCK DIAGRAM Power amplifier Power amplifier Limiter Limiter CH 1 INPUT THROUGH MONO ST EREO BRIDGE MODE 1 1 2 2 OUTPUT OUTPUT CH 2 INPUT LEVEL LEVEL THROUGH ...

Страница 11: ...Source To Channel 2 Input Signal Source Channel 2 Satellite Channel 1 Satellite Channel 2 Subwoofer Channel 1 Subwoofer AMPLIFIER BLOCK DIAGRAM for input modules with a sensitivity switch 775V 1 4V 32dB GAIN Power amplifier Power amplifier Limiter Limiter CH 1 INPUT THROUGH MONO ST EREO BRIDGE MODE LEVEL LEVEL ON OFF HI PASS FILTER 35Hz ON OFF HI PASS FILTER 35Hz 1 1 2 2 OUTPUT OUTPUT CH 2 INPUT T...

Страница 12: ...ER HI position AMPLIFIER BLOCK DIAGRAM for input modules with crossover CROSSOVER CROSSOVER HF LF HF LF HI FULL RANGE LO CROSSOVER LEVEL LEVEL HI FULL RANGE LO CROSSOVER Power amplifier Power amplifier Limiter Limiter CH 1 INPUT SWITCHED OUTPUT LO THRU HI SWITCHED OUTPUT LO THRU HI MONO ST EREO BRIDGE MODE 125Hz 125Hz 125Hz 125Hz ON OFF HI PASS FILTER 35Hz ON OFF HI PASS FILTER 35Hz 1 1 2 2 OUTPUT...

Страница 13: ...ite Channel 2 Subwoofer Channel 1 Subwoofer FRONT PANEL Power switch LEVEL input signal attenuators for channel 1 2 respectively ALARM LEDs Indicate alarm status and protection of the respective channel in case of DC output condition or powerful LF fluctuations output stage overheating Note See page 5 Thermal Protection CLIP overload LEDs Indicate overloading sound distortion and limiter activatio...

Страница 14: ... two channels drive two separate loads from two separate input signal sources BRIDGE two channels drive a common load from a single input signal source INPUT balanced input XLR female for Channel 1 in STEREO Channels1 and 2 in MONO BRIDGE mode MAINS IN power cord socket for 230V AC 50 60Hz grounded mains OUTPUT Channel 1 output Is used to connect a load speaker system to Channel 1 with a SPEAKON c...

Страница 15: ...on THROUGH line outputs for Channel 2 1 respectively XLR male Are used to deliver input signal along the respective channel to the input of another amplifier THROUGH connectors are parallel to INPUT connectors of respective channels GAIN input sensitivity switches for Channel 2 1 respectively Are used to select the input sensitivity 0 775V 1 4V or fixed gain 32 dB for respective channel INPUT Chan...

Страница 16: ...nal delivered to the output of the respective channel CROSSOVER switch for channel 1 2 respectively Selects the desired frequency range to be amplified HI LO FULLRANGE The BRIDGE mode the frequency range is set by Channel 1 CROSSOVER switch INPUT MODULE WITH CROSSOVER Option Linking up the Signal and Speakers in MONO Mode CAUTION Never attempt to jumper or otherwise link up any pins of output conn...

Страница 17: ...r loss to the load at other cable lengths For example if you plan to deliver 500Watts to 8 Ohm load through 20m of 1 5 mm2 cable the power loss in the cable would be 2 9 x 2 5 8 of 500W or 29W lost in the cable Wire Gauge Cable Resistance Cable power loss 8Ohm load 1 5mm2 2 0mm2 2 5mm2 4 0mm2 0 24 Ohm 0 18 Ohm 0 15 Ohm 0 09 Ohm 10 7 8 3 7 4 3 2 9 2 2 1 8 1 1 2Ohm load 5 7 4 3 3 6 2 3 4Ohm load Pow...

Страница 18: ...I V4 1800MkIII V4 2400MkIII V2 2400MkIII amplifiers are supplied with a three conductor grounded AC power cord and should be plugged into a standard 3 wire grounded electrical outlet which supplies 230VAC 50 60Hz Make sure to connect the amplifier only to sufficiently powerful power supply mains closer to a switch board If connected to weak power supply mains the output power of the amplifier may ...

Отзывы: