background image

4

To  signal  source

Channel  A

line  output

To  signal  source  Channel  B
line  output

LINKING OF INPUT SIGNAL TO AMPLIFIER

The Cutoff and Crossover Filters

The amplifier incorporates:

 high-pass fourth-order cutoff filter (signal slope 

 2

4 dB/oct.);

 fine-adjustable second-order low-pass crossover filter (signal slope 

 1

2 dB/oct.).

The high-pass fourth-order cutoff filter is used for elimination of signal LF components

which cannot be reproduced by the speaker system.

The basic model has the high-pass cutoff filter set to 45 Hz.

The  low-pass  crossover  filter  is  used  to  limit  the  amplified  frequency  range  to  be

compatible with the subwoofer application.

The cutoff point of the low-pass filter can be set by the control knob within the range

of 80 Hz to 350 Hz.

Built-in Parametric EQ

The EQ provides the parametric correction of the amplifier frequency response.

The correction is effected in three points with adjustment of the respective Q value and

boost/cut parameters. The EQ is preset by the manufacturer as requested by the customer.

The customer-required parameters are shown on the label pasted on the amplifier

casing.

9

Содержание DX1000MB

Страница 1: ...OWNER S MANUAL PARK AUDIO II www parkaudio2 com...

Страница 2: ...msgeneratedbyhighoutput powerdeliveredbytheamplifiermaybehazardoustoyourhearing Please takeadequate safety precautions WARNING The amplifier yields high output power The manufacturer shall not be held...

Страница 3: ...ry to ensure its flawless appearance After unpacking please check the unit for any physicaldamage Incase of damage please contact our local dealer Keep the shipping carton and all packing material as...

Страница 4: ...sed by reduced load impedance It disables the output signal of the respective channel for 0 5 second and then the amplifier gradually resumes its delivery DC Output Protection The amplifier s schemati...

Страница 5: ...her the overload condition and thermal protection active condition Input Section The input section incorporates two line input XLR female two line output XLR male low pass filter control knob output s...

Страница 6: ...asic model has the high pass cutoff filter set to 45 Hz The low pass crossover filter is used to limit the amplified frequency range to be compatible with the subwoofer application The cutoff point of...

Страница 7: ...rate normally albeit with less power The actual AC current consumption by the amplifier depends on the audio signal level and the load impedance For typicalaudio program materialwith the amplifier dri...

Страница 8: ...FILTER low pass filter cutoff point knob sets the bandwidth upper frequency 80Hz 350Hz BASS LEVEL input level control knob Used to adjust the level of the input signal applied to the power amplifier C...