ASSEMBLING THE PARI O-PEP
FIG.
A
1. Attach the lanyard to
the lower part
(FIG. A).
2. Insert the funnel in
the lower part
(FIG. B).
FIG.
B
FIG.
C
You have the option of using the lanyard to prevent the PARI O-PEP
from falling or being dropped during treatment. Children should
always be supervised when using the O-PEP especially when used
with the lanyard.
1. Sit in a relaxed, upright position.
2. Support the PARI O-PEP and hold it so that the mouthpiece is
horizontal to the floor.
3. Slowly inhale and then place your lips tightly, but comfortably around
the mouthpiece. (FIG. D)
4. Make sure that the holes in the upper part are unobstructed and not
covered by your hand.
5. Breathe out slowly and completely through your mouth and into the
PARI O-PEP slowly and for as long as possible. As you do this, tense
your cheek muscles and keep your cheeks taut.
6. Remove the PARI O-PEP from your mouth to inhale (do not attempt to
inhale through the device).
7. Repeat the cycle of breathing in and out for 10 to 15 breaths. End the
treatment session if the exertion becomes too great.
8. Treatment will not be effective if the patient breathes in too rapidly or
displays excess exertion to breathe.
NOTE:
The PARI O-PEP can be adjusted to the patient’s resonant
frequency by moving the O-PEP slightly up or down to achieve maximum
vibrations. See Figures E and F. These vibrations in the lungs can be felt
as the patient exhales. After establishing a comfortable position, the
patient can begin therapy.
PERFORMING TREATMENT
FIG.
D
FIG.
G
1. After cleaning your PARI
O-PEP, store it in the
nylon case as shown
(FIG. G).
STORING THE PARI O-PEP SYSTEM
4
5
6
© 2017 PARI Respiratory Equipment, Inc.
Manufactured for:
PARI
Respiratory Equipment, Inc.
2412 PARI Way, Midlothian, VA 23112 USA
Tel: 800.FAST.NEB (327.8632) and 804.253.7274
Fax: 804.253.0246 | [email protected]
www.pari.com
Part No. 018D0200 Rev A 02-17
CLEANING THE PARI O-PEP SYSTEM
1. Disassemble the PARI O-PEP and rinse the parts with warm,
running tap water for about 10 seconds.
2. Place the parts in a solution of warm tap water and liquid dish
soap for 5 minutes.
Note: Do not use chlorine bleach or other chlorine-containing
products or detergents.
3. Rinse the parts thoroughly with warm, running tap water for
about 30 seconds.
4. Air dry the parts on a clean, lint-free cloth. Reassemble PARI
O-PEP when dry and store.
FIG.
E
30°
FIG.
F
4. Screw the upper part
onto the lower part
(FIG. C).
3. Place the ball in
the funnel
(FIG. B).
Discard your PARI O-PEP after 6 month’s use