5 JBUS ADDRESS TABLE
JBUS address
(decimal)
Data
JBUS function
0
Model = 00C7h
3, 4
1
Version
3, 4
2
Power supply voltage (V/10)
3, 4
3
Temperature (°C)
3, 4
4
Quality 1s (1) (3)
3, 4
5
Distance 1s (2) (3)
3, 4
6
Quality 4s (1) (3)
3, 4
7
Distance 4s (2) (3)
3, 4
8
Quality 16s (1) (3)
3, 4
9
Distance 16s (2) (3)
3, 4
100
Standby / reactivation
command (4)
6
65524
Minimum clearance (mm)
6
65525
Maximum clearance (mm)
6
65529
Clearance specified with
fault (mm)
6
65533
Sensitivity (5)
6
65535
Slave number (*)
6
(*) 1 by default. If the existing slave number is unknown, use the
slave number 0 to enter the desired slave, connecting only one slave
to the RS485 line.
(1) Details of distance measurement quality:
[15-8] = echo amplitude, 0 to 255
[7] = presence of parasitic echoes
[6-4] = sensitivity, 0 to 7
[3-0] = number of valid echoes out of 1s, 0 to 15
(2) Details of distance measurement:
65535 (-1) = measurement in progress (following
reactivation)
65534 (-2) = measurement in progress (internal VCO
reset)
65533 (-3) = no echo
65532 (-4) = power supply voltage too low
65530 (-6) = echo removed by filtering (false echo)
65529 (-7) = incorrect echo shape
65528 (-8) = Echo outside authorised range
0 – 30000 = valid measurement available (mm)
(3) The radar makes several measurements per second, and the
averages over 1s, 4s and 16s. The 3 values are available in the
JBUS addressable space. The same applies for data relating to the
quality of this measurement.
(4) By default, the radar is activated. Enter the value 256 at the
address 100 to put the radar to sleep and 0 to reactivate it. When the
radar is on standby, the first JBUS query may not get a response. In
this case, the master must repeat its request within 2s.
(5) Most significant byte, from 0 to 7
6 SAFETY SYMBOLS AND MARKS
:
Hazard risk. Important information. Refer to the instructions for use.
: Read the instructions for use.
: Compliant with European Union and EFTA directives.
: European Directive 2002/96/EC of 27 January 2003 on waste electrical and electronic equipment (WEEE
Directive) was transposed in France by Decree No. 2005-829 of 20 July 2005.
Electrical or electronic appliances, and their spare parts and consumables must never be disposed of in household
waste.
PARATRONIC
has undertaken to set up an Individual Collection System.
PARATRONIC
waste electrical and electronic equipment should be returned by customers (End users) to our
company’s head office, at the following address:
PARATRONIC
- Zone Industrielle - Rue des Genêts, 01600 REYRIEUX, France
Service Recyclage DEEE
7 SAFETY INSTRUCTIONS
: WARNING:
The protection offered may be compromised if this appliance is not used as specified.
The specifications described in this document are subject to change by the manufacturer without notice.