BASIC SAFETY PRECAUTIONS: 
 

 

Equipment operation must always be conducted by trained personnel. 

 

All personnel at the immediate lift bag site must be properly suited up (protective clothing, helmet, 
eye protection, gloves, footwear, etc.) at all times. 

 

Follow instructions for full system set-up, operation, and teardown in the Cushion Manual.  

 

To avoid the possibility of serious injury or death, stay clear of the loads and keep others away. 

 

Do not exceed the rated capabilities of the Cushion, Controller, or Hose.  Excess pressure may 
result in personal injury. 

 

Control the load at all times with Stabilization Struts or cribbing.   

 

When using Stabilization Strut, make sure LockCollars follow the load at all times by adjusting 
them down as the load is lifted.  A LockCollar should never get more than 1” away from the tube 
body.     

 

DO NOT rapidly drop a load.  Lower the load carefully by SLOWLY releasing system pressure 
through the controller.       

 

Do not use a hose to carry or move attached equipment.  Stress may damage the hose and 
fittings which could cause personal injury and equipment failure. 

 
 

 

G3 CUSHION DEADMAN OPERATION: 

NOTE: For safety purposes, the Locking Ring on the inlet connection vented coupling is 
required to be rotated to the full lock position or the system will leak.   

 

1.

 

Attach  the  inlet  quick  connect  vented  coupling  on  the  G3  Cushion  Controller  to  a  regulated  air 
source.  

2.

 

Attach a safety inline relief valve to the outlet/delivery quick connect couplings being used on the 
G3  Cushion  Controller.  Check  that  the  safety  inline  relief  valve  shut-off  valves  are  closed  (full 
clockwise).  

3.

 

Attach an air hose(s) between the inline relief valve(s) and Cushion(s) being used.  NOTE: A 
different colored air hose should be used to permit the rapid and positive identification of the ALB 
connected to each side of the controller. 

4.

 

Turn the pressure regulator adjusting knob clockwise to increase the delivery pressure from 0 psi 
to 145 psi (10 bar). 

5.

 

Slowly open (turn counter-clockwise) the pressure regulator shut-off valve. The delivery pressure 
should remain at 145 psi (10 bar). 

6.

 

   Open the shut-off valve on the safety inline relief valve(s).  

7.

 

Press the green inflate button on the G3 Cushion Controller repeatedly to slowly inflate the  
Cushion to the required height or 14.5 psi (1 bar). Inflating the Cushion(s) slowly will minimize the 
possibility of shifting. If a second Cushion is interconnected to the controller, operate the second 
green inflate button to slowly inflate the second Cushion. The Cushions may be inflated 
simultaneously or alternately as desired by the operator. 

8.

 

To lower the load, adjust its height, or relief pressure from the Cushions(s), press the red deflate 
button on the G3 Cushion Controller.   

9.

 

With the Cushion(s) inflated to the desired height/pressure close (turn clockwise) the shut-off 
valve on the safety inline relief valve(s). 

 

 

Содержание G3 DUAL DEADMAN

Страница 1: ... INSTRUCTION SHEET G3 DUAL DEADMAN 14 5 PSI CUSHION CONTROLLER P N 22 887305G3 FEATURES VENTED QUICK CONNECT OPEN COUPLING INLET HOSE TO PRESSURE REGULATOR OR REGULATED AIR SOURCE QUICK CONNECT OPEN COUPLINGS IN LINES TO HOSES CUSHIONS HIGH VISABILITY GAUGES PROTECTED BY CONTROLLER BODY GAUGE LIGHT TO VIEW DURING LOW LIGHT SITUATIONS PROTECTED 14 5 PSI PRESSURE RELIEF VALVES 40 MICRON POROUS FILTE...

Страница 2: ...21 Back mount 1 5 38 1 mm with 14 5 psi 1 0 bar green scale and 14 5 30 psi 1 0 2 07 bar red scale Used to monitor system pressure the gauge is installed inside the controller housing see maintenance section for installation procedure Gauge weight 20 lbs 09 kg 2 G3 Deadman Gauge Light PN 22 890862 Ultra bright white LED flashlight with black polyurethane housing and PARATECH logo IPX 7 rated with ...

Страница 3: ...ed coupling is required to be rotated to the full lock position or the system will leak 1 Attach the inlet quick connect vented coupling on the G3 Cushion Controller to a regulated air source 2 Attach a safety inline relief valve to the outlet delivery quick connect couplings being used on the G3 Cushion Controller Check that the safety inline relief valve shut off valves are closed full clockwise...

Страница 4: ...uge in place and separate the gauge from the controller 2 Place the flats of the gauge base into a vice and unscrew using a 9 16 14 mm open end wrench 3 Discard the damaged gauge and replace it with PARATECH PN 22 890621 4 Apply 2 wraps of Teflon tape on the new gauge threads NOTE to prevent system contamination keep tape off of the bottom 2 gauge threads 5 Screw gauge back into the base and retig...

Страница 5: ...1 Using a T20 Torx Driver remove the 2 screws to the upper left and right of the gauge light 2 Fold back the cover plate to expose the gauge light NOTE The cover plate has been designed with a living hinge so it will not be damaged by folding back on itself 3 Remove and discard the old gauge light and replace it with PARATECH PN 22 890862 4 Fold the cover plate down and reinstall the 2 T20 Torx sc...

Страница 6: ...ch of Paratech Inc P O Box 1000 Frankfort IL 60423 USA P O Box 174 5260 Odense S Denmark Customer Service 800 435 9358 www paratech com Email Paratech paratech dk Phone 815 469 3911 Fax 815 469 7748 www paratech com E mail paratech paratech us ...

Отзывы: