DEVICE MAINTENANCE AND CLEANING
TRAINING
52
©
Parata
2014
How to adjust or replace the Perforation Blade
Removing the Anvil Assembly
1. With your left hand, grasp the anvil assembly using your thumb to hold the front end
around the depth adjustment screw, and your fingers to pull back on the wrinkle
preventer to clear the white paper guide on the second shutter.
2. Pull the anvil assembly off the guide pin up and to the left. it may be necessary to wiggle
the assembly forward and back while lifting the anvil assembly off.