background image

7

3)

Do not place the Z-12 on carpeting or any other material that could obstruct airflow
through the ventilation holes in the bottom of its chassis.

4)

Never stack the Z-12 between other components because hot air will quickly become
trapped and cause overheating of the amplifier and the other units. It’s best to mount
the Z-12 above your other components.

Connecting the Zonemaster Z-12

Refer to the drawing on Page 4

Connection Precautions

Leave the AC cord disconnected before and while making or changing any input, trigger, or
speaker connections. Make sure there is no strain or tension on any connections that could
cause them to eventually pull loose.

Input Connections & Input Assignment Switches

You can select or “assign” different inputs to each of the twelve amplifier channels. The four
position Input Assignment Switches designate the source from which each channel receives
its signals.

You can assign each input to receive its signal from the Main Left Input or Main Right Input,
a mono sum of both the Left and Right Inputs, or its independent input jack.

Input Assignment

Signal Origin

Switch Position

L

Left Input Bus

R

Right Input Bus

L+R

Left and Right Input Buses, mixed to mono

Local

The RCA Input jack for each channel

Main Left and Right Input Connections

The Left and Right Input jacks feed two signal paths (“buses”) that are distributed to all twelve
amplifier channels. The Input Assignment switches let you choose whether each of the twelve
amplifier channels receive an input from the Left or Right Input Bus or a mono sum of the Left
and Right Input Buses.

Looping Output Connections

The Right and Left Loop Out jacks provide a convenient way to connect an additional
amplifier to receive the same input signals as the Right and Left Main Inputs. Once you have
connected a source to the Z-12 Main In jacks you can connect the Loop Out jacks to the input
jacks of an additional amplifier. This feature eliminates the need for a “Y” connector between
your source, the Z-12, and the other amplifier.

Содержание ZoneMaster Z-12

Страница 1: ...1 O W N E R S M A N U A L ZoneMaster Z 12 High Current Amplifier www parasound com...

Страница 2: ...nnel into 8 Less than 0 2 THD 100 Watts Per Channel Pair Bridged into 8 Less than 0 2 THD 10 Amperes Peak Current Per Channel Direct Coupled with DC Servo Circuitry Encapsulated 1 2 kVA Toroidal Power...

Страница 3: ...This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of...

Страница 4: ...2 T15A 115 120 Area T8A 230V 250V Area AC 115 V 60 Hz AC 230 V 50 Hz Power Consumption 1100 W Normal Bridged Mono Ch 12 In Ch 11 Ch 12 Local R L R L Bus Local R L R L Bus Bridged To Prevent Fire Or Sh...

Страница 5: ...o n e m a s t e r Z 1 2 H i g h C u r r e n t A m p l i f i e r 1 2 3 4 5 6 7 8 9 10 11 12 Stand by On Off Au to On AC Line High Temp Power Switch Operation Status Indicators Rack Mount Holes Carry Ha...

Страница 6: ...sure that your cabinet or shelf can support its weight You should provide a separate shelf for your Zonemaster Z 12 rather that stacking it directly above or below other components The Z 12 front pan...

Страница 7: ...ves its signals You can assign each input to receive its signal from the Main Left Input or Main Right Input a mono sum of both the Left and Right Inputs or its independent input jack Input Assignment...

Страница 8: ...m controller to the Left and Right Input Bus 2 Set the Ch 3 Input Assignment switch to its R L position 3 Set the Ch 4 Input Assignment switch to its R L position 4 Connect the Ch 3 Speaker Terminals...

Страница 9: ...o AWG 12 To properly terminate the banana plugs follow these steps 1 Remove the insulating boot from the banana plug and slide it up onto one of the speaker wires Be sure to use the red boot for the p...

Страница 10: ...able to the red even number channel Ch 2 Ch 4 Ch 6 etc speaker terminal of the bridged channel pair 5 Connect the negative lead of the speaker cable to the red odd number channel Ch 1 Ch 3 Ch 5 etc sp...

Страница 11: ...ut Connection The Z 12 can be triggered on with an external DC voltage source that ranges from between 9Vand 12V ManyaudiovideocontrollerssuchastheParasoundAVC 2500havetrigger outputs for this task To...

Страница 12: ...nding on how you have configured the Z 12 you can use these controls to properly match the levels from zone to zone or channel to channel Each channel is marked on the top cover to identify levels wit...

Страница 13: ...the channel pair Temperature overheating Channel s are being overdriven Load impedance too low or short circuited wires Blown internal B or B fuse s LEDs not illuminated Remote enable is disabled by...

Страница 14: ...tain a Return Authorization RA number The RA number must be clearly marked on the outer carton only Ship the unit with adequate insurance and a copy of your purchase receipt inside to validate your wa...

Страница 15: ...0 03 TIM Unmeasureable Dynamic Headroom 1 5 dB Interchannel Crosstalk 50 dB at 1 kHz 40 dB at 20 kHz Input Impedance 47 k for each channel Input Sensitivity 1 2 V for full output S N Ratio 86 dB inpu...

Страница 16: ...16 2000 Parasound Products Inc Rev 1 1 Parasound Products Inc 950 Battery Street San Francisco CA 94111 415 397 7100 FAX 415 397 0144 www parasound com...

Отзывы: