Parasound Zhd Скачать руководство пользователя страница 2

IMPORTANT SAFETY INSTRUCTIONS

The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user  
to the presence of “dangerous voltage” inside the product that may constitute a risk of electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of  
important operating and maintenance instructions in the literature accompanying the product.

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE 
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

1. 

Read Instructions

 — Read all the safety and operating instructions before operating this product.

2. 

Retain Instructions

 — Retain safety and operating instructions for future reference.

3. 

Heed Warnings

 — Adhere to all warnings on the product and in the operating instructions.

4. 

Follow Instructions

 — Follow all operating and use instructions.

5.   

Cleaning

 — Unplug this product from the wall outlet before cleaning. Use a damp cloth for cleaning. 

Clean the outside of the product only.

6.   

Attachments

 — Do not use attachments that are not recommended by the product manufacturer; 

they may be hazardous.

7. 

Water and Moisture

 — Do not use this product near water.

8.   

Accessories

 — Do not place this product on an unstable cart or stand. The product may fall, causing 

bodily injury and damage to the product. A product and cart combination should be moved with care. 
Quick stops, excessive force, and uneven surfaces may cause the product and cart to overturn.

9.   

Ventilation

 — Slots and openings in the cabinet are provided for ventilation to ensure reliable opera-

tion of the product and to protect it from overheating. These openings must not be blocked or  
covered. This product should not be placed in a built-in installation such as a bookcase or rack unless 
proper ventilation is provided.

10.   

Power Sources

 — Operate this product only from the type of power source indicated on the label.  

If you are not sure of the type of power supply to your home, consult your dealer or local power  
company. This product is equipped with a three-prong grounding plug. This plug will only fit into a 
grounding power outlet. If you are unable to insert the plug into the outlet, contact your electrician  
to replace your obsolete outlet. Do not defeat the safety purpose of the grounding plug.

11.   

Power Cord Protection

 — Power supply cords should be routed so that they are not likely to be 

walked on or pinched by items placed upon or against them.

12.   

Lightning

 — Unplug the unit from the wall outlet for added protection during a lightning storm  

and when it is left unattended and unused for long periods of time. This will prevent damage to the  
product due to lightning and power line surges.

13. 

Overloading

 — Do not overload wall outlets or extension cords. This can result in a fire or electric shock.

14.   

Inserting Objects into Unit

 — Never push objects of any kind into this product through any openings; 

they may touch dangerous voltage points or short out parts that could result in fire or electric shock.

15.   

Servicing

 — Do not attempt to repair or service this product yourself. Opening or removing covers may 

expose you to dangerous voltage and other hazards. Refer all servicing to qualified service personnel.

16.   

Damage Requiring Service

 — Unplug this product from the wall outlet and refer servicing to quali-

fied service personnel under the following conditions: 

a)

 If the power-supply cord or plug is damaged.  

b)

 If liquid has been spilled into the product. 

c)

 If the product has been exposed to rain or water. 

d)

 

If the product does not operate normally by following the operating instructions. 

e)

 If the product has 

been dropped or damaged in any way. 

f)

 If the product exhibits a distinct change in performance.

17.   

Replacement Parts

 — When replacement parts are required, be sure the service technician has used 

replacement parts specified by the manufacturer. Unauthorized substitutions may result in fire, electric 
shock, and other hazards.

19.   

Safety Check

 — Upon completion of any service or repairs to this product, ask the service technician 

to perform safety checks to determine that the product is in proper operating condition.

20. 

Wall or Ceiling Mounting

 — Mount the product to a wall or ceiling only as recommended.

21.   

Heat

 — The product should be situated away from heat sources such as radiators, heat registers  

and stoves.

www.parasound.com

Содержание Zhd

Страница 1: ......

Страница 2: ...ong grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding plug 11 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them 12 Lightn...

Страница 3: ...lications 2 115 230v AC Selector Switch 3 Rack Mounting 3 Rear Panel Connections and Settings 4 Operating the Zhd 5 Operation by RS 232 6 If You Require Assistance 7 Warranty Repair 7 Specifications 8 TABLE OF CONTENTS 1 ...

Страница 4: ...ss you wish to operate it manually with its front panel buttons Please read this manual thoroughly before you begin installation Unpacking Carefully unpack your Zhd and these accessories Detachable AC power cord Remote control handset with two AAA batteries RS 232 control cable with DB9 connectors for use with Parasound 7 1 Channel Surround Controllers only not for use with other Parasound models ...

Страница 5: ...or 230v Rack Mounting The Zhd occupies only half the width of a single rack space in a standard 19 equipment rack For rack mounting you can fasten it to another Parasound Z Custom model by using the Parasound SBS Side by Side mounting kit You can also mount a single Zhd in the rack with the accessory Zblank panel The SBS includes four rack mount bolts plus four pairs of plastic shoulder washers Th...

Страница 6: ... amplified IR connecting block unlike Parasound Surround Controllers IR Remote Loop Jack The IR Remote Loop jack passes along the signal received at the IR Remote In jack to the next compo nent which is IR controlled It is provided as a courtesy to make your installation easier and neater RS 232 Control Port This is used for linking your Zhd to your Parasound 7 1 Channel Surround Controller a comp...

Страница 7: ...o depend on the quality of your HDMI cable and your HDMI source and receiving components You may need to experiment to determine if your particular setup benefits from the boost feature HDMI Boost selection is a one time setup operation which you won t need to change after your initial setup Note You may activate or de activate HDMI Boost only with the Input 1 and 5 buttons on the front panel not ...

Страница 8: ...s chart C 1 and C 2 7100 HDMI Input Video 1 DVD 1 Video 2 SAT 2 Video 3 VCR 3 Video 4 IN 4 4 Video 5 IN 5 5 Video 6 IN 6 No control Remember you might have renamed the source input on your C 1 C 2 or 7100 Note If you require a different input selection from above you must operate the Zhd manually or program an IR macro into your system s master remote Note for Crestron or AMX users If the RS 232 p...

Страница 9: ... your Parasound dealer first If the dealer can t help you with your problem we encourage you to call Parasound s Technical Service Department toll free at 1 866 770 8324 Monday Friday 8am 4pm Pacific time We can suggest other diagnostic tests you can easily perform If we determine that your Zhd should be returned to Parasound or an Authorized Parasound Warranty Center for inspection and possible s...

Страница 10: ...e Parasound warranty is not transferable 3 Unit s serial number was removed modified or defaced 4 Unit shows evidence of abuse and or misuse 5 Unit was modified in any way 6 A prior repair was attempted by an unauthorized repair station AC Power Requirement 110 120 V 220 240 V 50 60 Hz 5 watts Dimensions 91 2 Wide 10 Deep with connectors 2 High with feet 13 4 panel only 241 x 254 x 50mm 44 1mm pan...

Страница 11: ...NOTES Notes 9 ...

Страница 12: ...Rev 0 92 Parasound Products Inc 2005 ...

Отзывы: