background image

7

Configuring the Zamp v.2 for Mono operation

1. Turn the unit off.

2. Connect the single cable from your mono source to the Right channel Input jack.

3. Set the Stereo-Mono Switch to its Mono position.

4. Connect the positive lead of the speaker wire to the red R+ channel speaker terminal.

5. Connect the negative lead of the speaker wire to the red L+ channel speaker terminal.

Note: the R+ and L+ terminals are not spaced to accept a dual banana plug.

Automatic Turn On Options

For automation and convenience, the Zamp v.2 can be turned on and off by applying a
voltage to the Trigger In jack or by the presence of an audio signal at the input.

Auto On Select Switch

In the right position of the Auto On Switch, the Zamp v.2 is triggered on and off with an
ex9 V to + 12 V voltage. When the external voltage ceases the Zamp v.2 will turn
off immediately.

In the middle position of the Auto On Switch, the auto on function is disabled and the
Zamp v.2 can only be turned on and off manually by the On-Off button on the front panel.

In the left position of the Auto On Switch, the Zamp v.2 is turned on and off when an
audio signal is present at the Left and Right Input jacks. When the audio signal ceases, the
Zamp v.2 will remain on for about five minutes. This prevents unwanted turn off during
pauses in the music.

Trigger Input Connection

The Zamp v.2 can be triggered on with an external DC voltage source from +9 V to
+12 V. Many audio video controllers, and all Parasound audio video surround controllers
produced since 1997, include trigger outputs for this task.

To activate the Zamp v.2 with an external voltage source, plug one end of the provided
cord to the +12 V Trigger Input of the Zamp v.2 and the other end to the source
component’s +12 V output. Parasound sources will have a matching 2.5mm jack, but if
the source trigger is a terminal, you can cut off the plug at one end and attach the bare
wires. The lead with the white stripe on it corresponds to the plug’s tip and the unmarked
lead corresponds to the sleeve of the plug.

If the trigger voltage source is DC, the trigger plug tip must be positive and its sleeve
negative. The trigger circuit is optically coupled and thus only draws 15 mA of current for
activation.

Содержание Zamp v.2

Страница 1: ...1 O W N E R S M A N U A L www parasound com Zamp v 2 Zone Amplifier...

Страница 2: ...p v 2 11 Zamp v 2 Specifications 12 Features of the Parasound Zamp v 2 30 Watts Per Channel into 8 Less than 0 06 THD 45 Watts Per Channel into 4 Less than 0 06 THD 60 Watts Mono into 8 10 Amperes Pea...

Страница 3: ...This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of...

Страница 4: ...ound Products Inc San Francisco CA USA CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN 120 V 60 Hz 120 W Inputs Loop Out Level Sens Mono St In Out 12 V Trigger Audio Lift Gnd Auto On Man Z a m p Z o n e A...

Страница 5: ...away from heat sources such as heating ducts and radiators Always mount the amplifier horizontally Its panel dimensions are one rack space high 1 3 4 or 44 mm by one half rack space wide 9 1 2 or 242...

Страница 6: ...ransverse hole in the terminal s binding post Before inserting the wire twist its strands tightly between your fingers to prevent strays that might cause a short circuit You may want to tin the stripp...

Страница 7: ...e front panel In the left position of the Auto On Switch the Zamp v 2 is turned on and off when an audio signal is present at the Left and Right Input jacks When the audio signal ceases the Zamp v 2 w...

Страница 8: ...Power Connections and AC Grounding If possible plug your Zamp v 2 into the same AC outlet that powers your accompanying audio components and especially the system controller If you use a different AC...

Страница 9: ...If you suspect a problem with your Zamp v 2 first turn the unit off and check all your connections Another component or even a defective hookup cable may be causing the trouble If you hear hum turn of...

Страница 10: ...ranty repair contact us and we will advise you of the repair charges before you ship the unit to us The same packing and Return Authorization number requirements apply Important Notice before Shipping...

Страница 11: ...lector switch located on the bottom of the unit For 110 120 Vac operation Slide the switch into the position until the section of switch labeled 115 appears through the opening in the chassis For 220...

Страница 12: ...second Frequency Response 5 Hz 100 kHz 0 3 dB at 1 watt Total Harmonic Distortion 0 06 at full power 0 03 typical levels IM Distortion 0 03 TIM Unmeasureable Dynamic Headroom 1 5 dB Interchannel Cross...

Страница 13: ...13 2001 Parasound Products Inc Rev 2 0 Parasound Products Inc 950 Battery Street San Francisco CA 94111 415 397 7100 FAX 415 397 0144 www parasound com...

Отзывы: