background image

-6-

Introduction

Congratulations on your purchase of this precision audio component and thank you for your selection of
Parasound. The Parasound HCA-1205A and HCA-855A five channel amplifiers are virtually identical
in operation and sonic performance. However, the HCA-855A has slightly less power and is therefore
not THX certified like the HCA-1205A. Please take a few moments to read these instructions so that you
may fully understand the capabilities of your new Parasound power amplifier.

Unpacking Your Amplifier

Carefully unpack your amplifier and remove all the enclosed accessories. Be sure to inspect the unit for
any possible shipping damage. If you see any, contact your Parasound Dealer immediately. Save all the
packing material in case you need to ship the amplifier for repair. Before you proceed, find the serial
number located on the rear panel of your amplifier and record it here for reference:

Serial  #____________________

Date of Purchase____________________

Installing and Rack Mounting Your Amplifier

Place your amplifier away from heat sources such as air ducts and radiators. Always mount the amplifier
horizontally and make sure that your cabinet or shelf can support its weight. It is best to provide a separate
shelf for your amplifier rather that stacking it directly above or below other components.

With the use of the optional Parasound RMK-3, both the HCA-1205A and HCA-855A occupy three rack
spaces (5 1/4") in a standard 19 inch equipment rack. Be sure to use the heavy duty mounting bolts with
nylon shoulder washers on both sides of the faceplate to avoid scratching the amplifier’s front panel and
to help prevent ground loops. This mounting hardware is included with the RMK-3. When rack mounting
equipment, have someone help support the unit while you bolt the component to the rack rails.

Ventilation Requirements for Your Amplifier

To insure safe and reliable operation, it is very important that the amplifier has plenty of ventilation to
prevent overheating and automatic shut down from its thermal protection circuitry. Please observe the
following ventilation guidelines when installing your amplifier in a cabinet or other enclosed area:

1) If you are not using a fan, allow at least six inches on each side and above the amplifier, and do not
close off the front with a cabinet door or panel.
2) If you are enclosing the amplifier within an equipment cabinet, use a fan to draw in cool air and
exhaust warm air. Two vent holes are required: one for intake and one for exhaust.
3) Do not place the amplifier on carpeting that will obstruct the air flow into the bottom of the amplifier
chassis and heatsinks.
4) Avoid stacking components. If you do stack components, you must use a fan to circulate the warm air
that will quickly become trapped between them when they are powered on.

Making Connections to Your Amplifier

Leave the AC cord disconnected while making any input or speaker connections. When making
connections to the amplifier, make sure there is no strain or tension on the input leads, speaker wires, or
AC cord that could cause them to pull loose.

Содержание HCA-1205A

Страница 1: ...e n t P o w e r A m p l i f i e r H C A 8 5 5 A H i g h C u r r e n t P o w e r A m p l i f i e r Power Current Overload 3 5 4 1 2 AC Line Normal Standby H C A 1 2 0 5 A H i g h C u r r e n t P o w e...

Страница 2: ...0 000 uF filter capacitance in the HCA 1205A 1 kVA power transformer 68 000 uF filter capacitance in the HCA 855A Modular circuit board layout Massive toroid power transformer Multiple polystyrene fil...

Страница 3: ...This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of...

Страница 4: ...LE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE DC Trigger 12V GND Input Connectors and Level Control...

Страница 5: ...R SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE DC Trigger 12V GND Input Connectors and Le...

Страница 6: ...d 19 inch equipment rack Be sure to use the heavy duty mounting bolts with nylon shoulder washers on both sides of the faceplate to avoid scratching the amplifier s front panel and tohelppreventground...

Страница 7: ...f insulation and twist the wire s strands tightly to prevent strays that could cause a short circuit You may want to tin the stripped wire with solder to prevent it from fraying and oxidizing Polarity...

Страница 8: ...ED indicates that the AC cord is connected and that power is currently applied to the amplifier Standby Normal Operation LEDs TheredStandbyLEDwilllightwhentheamplifieristurnedoneitherwiththepowerswitc...

Страница 9: ...was probably be caused by your processor or one of the source components connected to it Frequently hum in home theater systems is caused by a grounding problem with the cable TV system Contactyourcab...

Страница 10: ...tortion 0 03 at full power 0 01 typical levels IM Distortion 0 03 TIM Unmeasureable Dynamic Headroom 1 5 dB Interchannel Crosstalk 80 dB at 1 kHz 60 dB at 20 kHz Input Impedance 33 k Input Sensitivity...

Страница 11: ...al Harmonic Distortion 0 03 at full power 0 01 typical levels IM Distortion 0 03 TIM Unmeasureable Dynamic Headroom 1 5 dB Interchannel Crosstalk 80 dB at 1 kHz 60 dB at 20 kHz Input Impedance 33 k In...

Страница 12: ...12 1999 Parasound Products Inc Parasound Products Inc 950 Battery Street San Francisco CA 94111 415 397 7100 FAX 415 397 0144 affordable audio for the critical listener...