OPERATING INSTRUCTIONS

 

 

 
 

When this OZGLOW heater has been assembled follow the lighting instructions 

on the data plate and test the heater operation. On the first light up or when the 

bottle  has  been  changed  it  may  take  several  minutes  to  purge  the  air  from  the 

pilot line.

 

 

Some  smoke  may  appear  around  the  emitter  screen  and  reflector  for  the  first 

minute or two of the initial light up.

 

 

1.

 

Depress the control knob and rotate anti 

clockwise to the pilot position.

 

2. 

View the pilot through the pilot hole near the 

burner. 

 

3. 

Hold  the  knob  in  the  pilot  position  until  the 

pilot  has  been  alight  for  15  seconds.  If  the 

pilot does not light repeat steps 1 

– 3. 

 

 

Rotate the knob anti clockwise from the pilot 

position to either the high or low positions.

 

 

Rotate  the  knob  clockwise  to  the  pilot 

position.  If  you  rotate  the  knob  fully 

clockwise the pilot will also turn off.

 

 

 

 

 

 

 

 

 

 

 
 

© PARASOL HEATERS AUSTRALIA

 

 

MELBOURNE 61 3 9549 4466 | SYDNEY 61 2 9624 4486 | BRISBANE 61 7 3200 7877 

www.parasolheaters.com.au

 

 

Created on 24/09/2015

 

Page 8 of 11

 

Содержание OZGLOW F40

Страница 1: ...ater Instructions OZGLOW F40 Permanent Installation PARASOL HEATERS AUSTRALIA MELBOURNE 61 3 9549 4466 SYDNEY 61 2 9624 4486 BRISBANE 61 7 3200 7877 www parasolheaters com au Created on 24 09 2015 Page 1 of 11 ...

Страница 2: ...L MAINTENANCE 4 DIMENSIONS and COMPONENTS 5 UNIT CLEARANCE 6 UNIT CLEARANCE PATIO RESTAURANT 7 HEATER SPACING 7 OPERATING INSTRUCTIONS 8 HEATER ASSEMBLY INSTRUCTIONS 9 WARRANTY 11 PARASOL HEATERS AUSTRALIA MELBOURNE 61 3 9549 4466 SYDNEY 61 2 9624 4486 BRISBANE 61 7 3200 7877 www parasolheaters com au Created on 24 09 2015 Page 2 of 11 ...

Страница 3: ...come with a 12 month domestic or 90 day commercial limited warranty and are fully serviceable with readily available parts if required Delivery is available throughout Australia and overseas The F40 Permanent Installation heater features 40 mj hr input rating 100 safety control Constant Pilot Piezo Ignition No electrical connections Corrosion resistant construction IAPMO GMK 10286 PARASOL HEATERS ...

Страница 4: ...s OZGLOW heater should be inspected before each use Particular attention should be given to the hose assembly to make sure there is no signs of damage or wear and tear o If the flame becomes excessively long and yellow or if soot builds up on the emitter mesh turn the heater off and call a qualified service person o Keep this OZGLOW heater free of cobwebs and as dust free as possible o If the flam...

Страница 5: ...nent Installation DIMENSIONS and COMPONENTS Overall height 2400mm Overall width 890mm PARASOL HEATERS AUSTRALIA MELBOURNE 61 3 9549 4466 SYDNEY 61 2 9624 4486 BRISBANE 61 7 3200 7877 www parasolheaters com au Created on 24 09 2015 Page 5 of 11 ...

Страница 6: ...following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no more than two walls Within a partial enclosure that includes an overhead cover and more than two walls the following shall apply At least 25 of the total wall area is completely open and At least 30 of the remainin...

Страница 7: ...No air heating efficiency is counted on in this installation Illustrates the same patio with a 2 5m high protective wall enclosing the patio Only six heaters are required for warmed air will remain within the enclosure and compound the direct radiant warming effect HEATER SPACING PARASOL HEATERS AUSTRALIA MELBOURNE 61 3 9549 4466 SYDNEY 61 2 9624 4486 BRISBANE 61 7 3200 7877 www parasolheaters com...

Страница 8: ... light up 1 Depress the control knob and rotate anti clockwise to the pilot position 2 View the pilot through the pilot hole near the burner 3 Hold the knob in the pilot position until the pilot has been alight for 15 seconds If the pilot does not light repeat steps 1 3 Rotate the knob anti clockwise from the pilot position to either the high or low positions Rotate the knob clockwise to the pilot...

Страница 9: ...egulator for LPG models the pipe screws straight into the bottom of the heater head 2 Fit the pole over the pipe assembly and using the screws supplied fix the pole to the heater head Make sure the regulator adjustment lines up with the hole in the pole 3 Concrete the pole into the ground to a depth of 450mm PARASOL HEATERS AUSTRALIA MELBOURNE 61 3 9549 4466 SYDNEY 61 2 9624 4486 BRISBANE 61 7 320...

Страница 10: ... the gas valve Check for gas leaks Points to remember Check all joins for gas leaks Test fire the heater and check the gas pressure All pressure details are on the data plate If the heater cannot be adjusted properly contact Parasol Heaters Australia PARASOL HEATERS AUSTRALIA MELBOURNE 61 3 9549 4466 SYDNEY 61 2 9624 4486 BRISBANE 61 7 3200 7877 www parasolheaters com au Created on 24 09 2015 Page...

Страница 11: ... o Warranty is limited to the heater head being returned to our factory for repair or replacement parts o Parasol Heaters Australia Pty Ltd will not be liable for any other expenses to the customer except as stated above This heater is manufactured in Australia by PARASOL HEATERS AUSTRALIA 12 Yiannis Court Springvale VIC 3171 Australia PARASOL HEATERS AUSTRALIA MELBOURNE 61 3 9549 4466 SYDNEY 61 2...

Отзывы: