THE UV LAMP(S) WILL NOT COME ON
  

If this occurs upon initial start-up, the problem could be caused by a 
number of issues. All ULTRA UV units come with the pressure switch 
disabled. Make sure the electric is off, remove the cover and check to see 
that both wires are connected to the pressure switch. See page 10.

a.  The pressure switch is open. This can be caused by low pressure in your

system. Make sure the pump is ON (the UV lamp(s) will only light when
there is 5 PSI (0.35 Bar) water pressure inside your ULTRA UV unit’s
reactor). Verify that the pressure gauge reads 5 PSI or more. If it does
not read at least 5 PSI, reduce the flow exiting the ULTRA UV unit by
partially closing the valve on the discharge piping exiting the ULTRA UV
unit. This will increase the pressure inside the ULTRA UV reactor. To check
the pressure switch operation, unplug or turn off the breaker, remove the
enclosure cover on the top of the unit. Move the wire on the pressure
switch from the bottom post to the unused post on the top. Turn on the
power and if the lamps illuminate the pressure switch is a bad.

b.  The UV lamp(s) has/have become disconnected from the lamp

connector(s). Disconnect the power servicing the ULTRA UV unit, open
the electrical enclosure cover and confirm the lamp connector(s) is/
are firmly locked together. At the same time, check all exposed wires
for a possible loose connections. Re-establish power ONLY after the
electrical enclosure cover has been re-installed on the ULTRA UV unit.

c.  Verify that the electrical cord is plugged into an energized electrical

outlet or properly connected to the power source. Test the electrical
outlet. You should confirm the availability of the same power as
indicated on the electrical label on your ULTRA UV unit.

THE UV LAMP(S) IS/ARE NO LONgER ON

If this occurs after the unit has been operating successfully for a period of time.
a.  One or more lamps have burned out. Replace the UV lamp(s).

b.  A ballast has burned out. Contact your supplier or Paramount for

assistance in obtaining a new ballast.

c.  Verify that the electrical outlet where the ULTRA UV unit is plugged into

has the proper voltage and the cord is securely plugged into the outlet
or connected to the power source.

Содержание Ultra UV 004-422-2025-00

Страница 1: ...precautions should always be followed including the following WARNING Follow all applicable electrical codes Turn off power at main source before making any electrical connections or servicing the un...

Страница 2: ...ting The UV Unit On A Solid Base 6 Plumbing The Ultra UV Unit 7 Gluing Piping To The UV Unit 8 Providing Electrical Power To The Ultra UV Unit 8 Electrical Bonding Grounding 9 Pressure Switch 9 Connec...

Страница 3: ...cm2 30 mJ Confirm the size unit your application needs by using the sizing charts on page 2 and 3 to obtain the proper maximum system killing power CAUTION DO NOT USE THIS UNIT FOR POTABLE DRINKING W...

Страница 4: ...30V w 2 UV C Lamps w SS Reactor 004 422 2022 00 120V w 2 UV C Lamps 004 422 2029 10 1 20V w 2 UV C Lamps w SS Reactor 80 18 2 9600 36 3 14400 54 5 004 422 2027 00 230V w 3 UV C Lamps 004 422 2029 60...

Страница 5: ...6 004 422 2026 00 230V w 2 UV C Lamps 004 422 2029 50 2 30V w 2 UV C Lamps w SS Reactor 004 422 2022 00 120V w 2 UV C Lamps 004 422 2029 10 1 20V w 2 UV C Lamps w SS Reactor 80 18 2 57600 218 0 38400...

Страница 6: ...tra UV body The 4 outlets top and 4 inlets bottom provide the most versatile piping alternatives for the installer The Ultra UV unit comes with 2 each 2 inch or 63mm inlet and outlet unions Multiple i...

Страница 7: ...and with bypass Plumbing the ULTRA UV units in a series for large bodies of water with excessive flow rates Figs 2a multiple port Plumbing Without and with bypass Be sure to use the appropriate amoun...

Страница 8: ...te this voltage At 120V the power draw is 2 6 Amps maximum for a 4 lamp system This low power consumption makes operating your ULTRA UV unit very economical Your Ultra UV 120V unit is supplied with a...

Страница 9: ...RLY Paramount Recommends you have this important work done by a Licensed Electrical Technician Pressure Switch The ULTRA UV unit is equipped with a pressure switch that does not allow the UV lamp s in...

Страница 10: ...nded bypass valve then turn on the circulation system to ensure all debris is blown out of the plumbing Open the bypass and check for plumbing leaks and or leaks caused by damaged quartz tube Water Ch...

Страница 11: ...p 2 allow at least 15 minutes for the bulbs in the unit to cool off 2 NEVER REMOVE THE ELECTRICAL ENCLOSURE COVER WITHOUT FIRST UNPLUGGING OR TURNING OFF THE CIRCUIT BREAKER POWER SOURCE FOR THE ULTRA...

Страница 12: ...the way to get a better grip or to use a tool Remember to replace ballast 6 Carefully lift the compression washer from the top of the quartz tube making sure not to lose the black gasket that cushions...

Страница 13: ...ube doing so can result in a leak and possible damage to your UV unit 10 To reinstall the quartz tube place the O ring 2 inches from the top of the outside of the quartz tube Fig 17 Place the quartz t...

Страница 14: ...e of the black threaded sleeve and the quartz tube Check and make sure it is seated evenly around the circumference of the quartz tube Screw on the quartz sealing aluminum nut hand tight plus turn 13...

Страница 15: ...d any body oils on lamp s Oils will create hot spots and greatly shorten lamp s life Carefully lift the lamp s from the quartz tube Fig 24 3 With the lamp s removed from the unit pull off the black bo...

Страница 16: ...tures are considerably above freezing Option 2 Leaving the unit in place for the winter Turn off the power to the unit Remove the drain plug and allow all of the water to drain from the unit Disconnec...

Страница 17: ...re Any Residual Effect From UV No All of the sanitizing is done in the reactor Can The Ultra UV Unit Be Mounted Horizontally No vertical mounting is required to maintain the weatherproof integrity of...

Страница 18: ...f the breaker remove the enclosure cover on the top of the unit Move the wire on the pressure switch from the bottom post to the unused post on the top Turn on the power and if the lamps illuminate th...

Страница 19: ...p life before the lamp s is are turned ON a If the top of a ULTRA UV unit is located below the water level of the pond or pool there is a static head of water that causes pressure to be found inside t...

Страница 20: ...our chemical manufacturer s specifications f Your unit is not sized for the flow and duration specific to your pool The GFCI Has Tripped If you have installed a GFCI on your ULTRA UV application the G...

Страница 21: ...place that ballast Refer to page 20 for the proper ballast part number Reset the GFCI and if it does not trip attach the electrical plug to a UV lamp One at a time if multiple lamps are present in you...

Страница 22: ...lamp ballast 2 Lamp unit requires 1 dual lamp ballast 3 Lamp unit requires 1 single lamp ballast 1 dual lamp ballast 4 Lamp unit requires 2 dual lamp ballast 1 2 3 4 5 6 7 8 11 10 9 12 16 13 15 14 17...

Страница 23: ...ivolt Ballast 1 Lamp 8 005 422 2009 01 Advance Intellivolt Ballast 2 Lamp 9 005 422 2009 10 Pressure Switch 10 005 422 9010 00 Ballast Mounting Bracket 11 005 422 2009 05 Pressure Gauge 12 005 422 200...

Страница 24: ...MITATIONS No warranty extends to any part of the PP SS parts or components which is caused by any of the following conditions or events 1 Defects or failures caused by abuse lack of responsible care l...

Отзывы: