![Paramount Fitness SM2-25 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/paramount-fitness/sm2-25/sm2-25_installation-and-operation-manual_3644750011.webp)
9
1. An electrical supply should be available within the reach of the power cord. Do not use extensions to connect the
machines power cord to the electrical supply.
2. Before making the electrical connections, read the specifications on the rating plate to ensure that they comply
with those of the electrical supply. Electrical connection should be made by a qualified service technician who will
observe all applicable safety codes and the national electrical codes.
Australia / New Zealand
- AS/NZS3000
Wiring Rules.
When connecting this electric appliance to the mains supply, ensure that the following is carried out:-
An isolating switch is fitted within 2m of the appliance, but not on the appliance and in such a position that the
user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary polychloroprene or
other equivalent synthetic elastomer sheathed cord (as per AS / NZS 3191 part 2.10.11. or IEC 60245-IEC-57)
e.g. HO5 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating and the supply cord
shall be protected against any mechanical or thermal damage.
A grommet is fitted for the power supply cord entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance for the current
drawn on that line.
Once the electrical connection has been made, the mixer is ready for use.
Electrical Supply Requirements - refer to the ‘Specifications’ Section.
Before using the Spiral Mixer, make sure it is rotating in the correct direction.
1. Connect the electrical supply to an appropriate socket and turn ‘On’.
2. Start the mixer to check the direction of rotation of the kneading spiral and the bowl. When viewed from above,
both kneading spiral and bowl should rotate clockwise. The arrow on the bowl indicates the correct rotation of
the bowl. If the rotation direction is incorrect, swap any two phases to reverse the rotation direction.
3. Test the operation of the safety emergency stop button. The machine must stop operating immediately.
4. Test the operation of the microswitch cut-out on the bowl safety cover. When the cover is lifted the machine
must stop immediately.
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
Содержание SM2-25
Страница 1: ...243483 1...
Страница 22: ...20 400 415Vac 3PH PE...
Страница 23: ...21 400 415Vac 3PH PE...
Страница 27: ...25...
Страница 28: ...26...
Страница 29: ...27...
Страница 30: ...28...
Страница 31: ...29 Part No Part Name Part Code Specification...
Страница 32: ...30 Part No Part Name Part Code Specification...
Страница 33: ...31...
Страница 34: ...32...
Страница 35: ...33...
Страница 36: ...34...
Страница 39: ...37...
Страница 40: ...38...
Страница 41: ...39...
Страница 42: ...40...
Страница 45: ...43...
Страница 46: ...44...
Страница 47: ...45...
Страница 48: ...46...
Страница 51: ......