ANTI-ENTRAPM ENT DEBRIS DRAIN

ANTI-ENTRAPM ENT DEBRIS DRAIN

295 East Corporate Place  •  Suite 100  •  Chandler, AZ 85225

Toll Free: 1.800.621.5886  •  Phone: 480.893.7607  •  Fax: 480.753.3397

[email protected]  •  www.1Paramount.com

MDX0805          004-027-8790-00          REV030509

MDX

²

INSTALLATION MANUAL

VINYL POOLS

SUBMERGED SUCTION OUTLET

FOR MULTIPLE DRAIN USE

FOR USE ON FLOOR

SEE SPECIAL INSTRUCTIONS

FOR CALIFORNIA AND

FLORIDA ON PAGES

4 AND 5

Notice to Installers:

Read and follow these instructions. Give these instructions to

the facility owner to keep for future reference. Follow all codes

and regulations that apply to the design, installation and use

of suction outlet fittings.

WARNING:

MDX² and SDX must be installed in accordance

with Paramount's written instruction manual, and in conformi-

ty with applicable Federal, State, Local and Swimming pool

industry building and safety codes.

U.S. Patent No.: 6,810,537, 7,089,607, 7,178,179

Safety compliant according to the Virginia Graeme Baker

Pool and Spa Safety Act ASME A112.19.8 - 2007

Содержание MDX2 retro

Страница 1: ...A ON PAGES 4 AND 5 Notice to Installers Read and follow these instructions Give these instructions to the facility owner to keep for future reference Follow all codes and regulations that apply to the...

Страница 2: ...all ASME A112 19 8 2007 listed drains suction covers and debris removal systems This is the ONLY approved option for preventing Hair Entrapment Hazards the leading cause of suction related injuries De...

Страница 3: ...make sure it is not possible to exceed 90 GPM 340 LPM In the event of one suction outlet being completely blocked the remaining suction outlets serving that system shall have a flow rating capable of...

Страница 4: ...SUCTION OUTLET VACUUM BREAKER VENTTOAIR 5 FT MIN 5 1 2 FT MAX PLUG 2 1 2 SIDE PORT IF NOT USING HYDROSTAT PLUG 2 PORT Trunk line must be sized to meet maximum velocity requirements for suction plumbin...

Страница 5: ...plumbing per local code METHOD2CAWITHOUTCANISTER WITHVENT 51 2FT MAX 5FT MIN 21 2 TOPUMP VACUUMBREAKER VENTTOAIR PLUG21 2 SIDEPORT IFNOTUSINGHYDROSTAT PLUG2 PORT 21 2 X18 WATERLINE MDX2 MDX2 2 Trunk...

Страница 6: ...umbing per local code MDX2 Note Canister requires 1 equalizer line through pool wall Not Shown Note Canister requires 1 equalizer line through pool wall Not Shown METHOD2CAWITHCANISTER WITHVENT 51 2FT...

Страница 7: ...CANISTER WITH VENT TO PUMP 2 1 2 2 1 2 2 1 2 X 18 1 1 2 PLUG 2 1 2 SIDE PORT IF NOT USING HYDROSTAT PLUG 2 PORT SDX 2ND SUCTION OUTLET VACUUM BREAKER VENTTOAIR Trunk line must be sized to meet maximum...

Страница 8: ...rain cover exposing a suction risk This port is for the purpose of a hydrostat only If a hydrostat is not used plug this port from bottom with pipe and cap Do not install any suction equipment pump to...

Страница 9: ...4 4 Install five 5 self tapping screws Fig 5 through the SDX Bulkhead Support with the T25 Security Screwdriver Fig 6 Secure the screws without over tightening 5 Cut the Vinyl Liner out of the center...

Страница 10: ...ove grate from second suction and install a 13 blow through plug and blow line to achieve airlock 2 If 3rd suction line is installed remove grate install a 13 blow through plug and blow line to achiev...

Страница 11: ...iously described if skimmer is tied into canister repeat procedure to skimmer 4 Bottom port of canister to pump may require an extended pipe for ease of blowing out Install and blow out line from cani...

Страница 12: ...Pipe Size 15 005 252 1611 00 Plug Pressure Test 2 w O Ring 4 pcs 16 004 172 2212 XX SDX High Flow Safety Drain 2 pk XX Color Code 17 005 252 0821 00 Screw 10 X 1 1 4 TORX W PIN SS B 12 pcs 18 005 252...

Отзывы: