background image

7

WITH CANISTER

WITHOUT CANISTER

CALIFORNIA INSTALLATION METHOD 1

WITH CANISTER AND MV FUSE

ENLARGED SUCTION ELEMENT

IF NOT USING HYDROSTAT PORT

PLUG 2" PORT

SDX2

2ND SUCTION OUTLET

TO PUMP

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

2 1/2"

EQUAL SIZE AND LENGTH

FROM TEE TO EACH DRAIN

MV FUSE IN

CANISTER

CALIFORNIA METHOD 1 WITH

DECK CANISTER AND MV FUSE

ENLARGED SUCTION ELEMENT

IF NOT USING HYDROSTAT

PLUG 2" PORT

SDX2

2ND SUCTION OUTLET

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

2 1/2"

EQUAL SIZE AND LENGTH

FROM TEE TO EACH DRAIN

TO PUMP

MV FUSE DECK SIDE

*Note: Canister requires 1½” equalizer line through pool wall. (Not Shown)

IF NOT USING HYDROSTAT

PLUG 2" PORT

ENLARGED SUCTION ELEMENT

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

MV FUSE IN

CANISTER

CALIFORNIA METHOD 2 WITH CANISTER AND MV FUSE

2 1/2" OR 3"

TO PUMP

IF NOT USING HYDROSTAT

PLUG 2" PORT

CALIFORNIA INSTALLATION METHOD 1 

WITHOUT CANISTER, WITHOUT MV FUSE

2 1/2"

ENLARGED SUCTION ELEMENT

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

TO PUMP

EQUAL SIZE AND LENGTH

FROM TEE TO EACH DRAIN

SDX2

2ND SUCTION OUTLET

CALIFORNIA INSTALLATION METHOD 1 

WITH CANISTER, WITHOUT MV FUSE

IF NOT USING HYDROSTAT

PLUG 2" PORT

ENLARGED SUCTION ELEMENT

TO PUMP

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

2 1/2"

EQUAL SIZE AND LENGTH

FROM TEE TO EACH DRAIN

SDX2

2ND SUCTION OUTLET

*Note: Canister requires 1½” equalizer line through pool wall. (Not Shown)

IF NOT USING HYDROSTAT

PLUG 2" PORT

2 1/2" OR 3"

CALIFORNIA METHOD 2 WITH CANISTER WITHOUT MV FUSE

TO PUMP

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

ENLARGED SUCTION ELEMENT

CALIFORNIA METHOD 2 WITH DECK FUSE

IF NOT USING HYDROSTAT

PLUG 2" PORT

2 1/2" OR 3"

ENLARGED SUCTION ELEMENT

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

TO PUMP

MV FUSE DECK SIDE

IF NOT USING HYDROSTAT

PLUG 2" PORT

2 1/2" OR 3"

CALIFORNIA METHOD 2 WITHOUT CANISTER, WITHOUT MV FUSE

ENLARGED SUCTION ELEMENT

TRUNK LINE MUST BE

SIZED TO MEET MAXIMUM

VELOCITY REQUIREMENTS

FOR SUCTION PLUMBING

PER LOCAL CODE.

TO PUMP

*Note: Canister requires 1½” equalizer line through pool wall. (Not Shown)

*Note: Canister requires 1½” equalizer line through pool wall. (Not Shown)

Compliant with ANSI/APSP - 7 - 2006

MDX-R3 INSTALLATION FOR CALIFORNIA

Содержание MDX-R3

Страница 1: ...CIAL INSTRUCTIONS FOR CALIFORNIA ON PAGE 7 Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ANSI APSP 16 2011 Compliant with ANSI APSP 7 2006 WARNING MDX R3 and SDX2 mus...

Страница 2: ...perly secured or missing because these conditions increase the chance of death or serious injury from entrapment If a drain cover is discovered damaged cracked broken loose clogged not properly secure...

Страница 3: ...ety begins with a professional design that includes a quality suction system installed by a certified contractor Certified builders will address the following issues when designing and installing a pr...

Страница 4: ...aining suction outlets serving that system shall have a flow rating capable of the full flow of the pump s for the specific suction system NOTICE MDX R3 VGB COMPLIANT DEBRIS DRAIN STANDARD POOL DESIGN...

Страница 5: ...STER AND MV FUSE MV FUSE DECK SIDE SDX2 2ND SUCTION OUTLET 2 1 2 2 1 2 ENLARGED SUCTION ELEMENT IF NOT USING HYDROSTAT PLUG 2 PORT TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SU...

Страница 6: ...PER LOCAL CODE TO PUMP TO PUMP TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SUCTION PLUMBING PER LOCAL CODE 2 1 2 OR 3 ENLARGED SUCTION ELEMENT METHOD 2 WITH DECK FUSE IF NOT USI...

Страница 7: ...OR SUCTION PLUMBING PER LOCAL CODE TO PUMP EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN SDX2 2ND SUCTION OUTLET CALIFORNIA INSTALLATION METHOD 1 WITH CANISTER WITHOUT MV FUSE IF NOT USING HYDROSTAT PL...

Страница 8: ...aramount recommends the use of the 2 thread plug provided Do not use check valves here that are prone to sticking open causing the need to open the drain cover exposing a suction risk If a hydrostat i...

Страница 9: ...location for the SDX2 drain Additional SDX2 drains may be used 2 For Steel Wall Make one 4 hole using a Greenlee Standard Round Knockout Punch Greenlee com Cat No 742BB UPC No 19978 For Plastic Wall...

Страница 10: ...s without over tightening Fig 4 Fig 5 WITH CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2 1 Remove grate from wall drain and install a 13 blow through plug...

Страница 11: ...11...

Страница 12: ...ug 4 with O Ring 11 2 Pipe Not Included Cap If Not Used 12 2 Cap Not Included Cap If Not Used 13 005 252 5524 00 Enlarged Suction Element 14 005 252 2550 00 Coupler Reducer 4 X 2 3 005 272 0841 00 Scr...

Отзывы: