![Paramina Typhoon Open 13E Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/paramina/typhoon-open-13e/typhoon-open-13e_user-manual_3639300036.webp)
User Manual -
Typhoon Open –
01/2018 edition
.
PARAMINA SA
– Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
- website:
www.paramina-compressors.com
36
6.
Remove the coalescing cartridge & cover by pulling upwards.
7.
Lay a small amount of silicone grease on the o-rings of filter’s base. If there is a trace of damage on the o-
rings, replace.
8.
Install the new coalescing cartridge & cover on filter’s base by fastening it down with your hand.
9.
Wrap a small amount of Teflon around the thread of the tube connector.
10.
Clean the inside of the filter housing with a clean cloth.
11.
Screw the filter housing back on its base.
12.
Remove the new A.C.-M.S. cartridge from their protective case. Be sure that packaging is not punctured.
If it is damaged do not use it.
13.
Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
14.
Replace the two o-rings of the cartridge connector, lay a small amount of silicone grease on the new o-
rings and then screw the connector on the new A.C.-M.S. cartridge.
15.
Place the new A.C.-M.S. cartridge in the filter housing and fasten it down by hand on the tube connector
(see also drawing nr. B).
16.
Lay a small amount of silicone grease on the o-rings of the filter head. If there is a trace of damage on the
o-rings, replace.
17.
Screw the filter head carefully by hand with light pressure until it fits evenly to the filter housing.
Do not screw really tight, while screwing cartridges or connectors inside filter’s housing.
FILTER HEAD & FILTER HOUSING SHOULD BE ADJOINED ON TOP WHEN REINSTALLING.
Parts & Codes
Code
Description
Qty
208611492
Filter complete
1
208620002
Filter housing aluminum
1
208620022
Filter base
1
208620011
Filter head for Bleed Valve
1
208000082
Bleed Valve
1
137000080
AC/MS cartridge (active carbon/molecular sieve)
1
137000100
AC/MS/HP cartridge (active carbon/molecular sieve/hopcalite)
208000033
Connector cartridge
1
127505802
O-ring c.c. (connector cartridge)
2
137800000
Coalescing pre-filter Cover
1
306049631
Coalescing pre-filter
1
133000092
Handle
1
208000071
Tube connector
1
127616882
O-ring filter head & base
2
190000080
Manual drain complete with seat
1
190008112
Manual drain’s seat
1