background image

 

 

Press

Upper

part

Attach the Wall Mount Bracket (if not fitted) 
to the switch case using the screws supplied 

Mount the switch to the required surface 
using appropriate fixings 

 

7.

 

Installation Procedures 

 

7.1

 

  DIN Rail Installation 

 

 
 

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 

 
 

7.2

 

  Wall Mount Installation 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attach the DIN Rail Bracket (if not fitted) to 
the switch case using the screws supplied 

Clip the upper edge of the bracket onto the 
DIN Rail and push to latch the bottom strip 

Содержание PDT-PIN-7002-MP-I

Страница 1: ...Operations Manual PDT PIN 7002 MP I Revision 1 0 September 2022...

Страница 2: ...st 4 5 Product Overview 5 6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 RJ45 Ports 6 6 3 Power Supply Connector 6 7 Installation Procedures 7 7 1 DIN Rail Installation 7 7 2 Wall Mount Instal...

Страница 3: ...1 Revision History Date Rev By Comments Checked Date 13 09 2022 01 JF Initial Release SC 13 09 2022...

Страница 4: ...ation Description AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device...

Страница 5: ...and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings and cautionary statements could lead t...

Страница 6: ...compliant with IEEE 802 3ab This device incorporates a voltage booster circuit which allows for full support of IEEE 802 3 af at PoE PoE at 48VDC even with a 12VDC Power Supply making it suitable for...

Страница 7: ...r Green OFF PoE Output On ON PoE Output Off 6 2 RJ45 Ports The Front Panel has 2 RJ45 Ports the DATA IN Ports is used as the Data Input Port and are not PoE compatible The PoE OUT Ports should be used...

Страница 8: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Страница 9: ...is wired correctly and correctly inserted into the switch power connector housing 8 2 RJ45 Connections Ensure all required RJ45 Ports are connected correctly using CAT5e cable or better to the client...

Страница 10: ...45 Data Input 2 x RJ45 Power Data Output PoE Power DC In 2 Pin Terminal Block POE Standard IEEE 802 3af IEEE 802 3at Port RJ45 Power Budget Max 60W total Single Channel Max 60W ENVIRONMENTAL Operating...

Страница 11: ...tic Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity EN 61000 4 6 2014 Power...