Installation Procedures 

 

This device may be used on a desk-top or it can be installed in a 19” rack enclosure. Before 
installation into a rack enclosure, the 2 x L-Shaped brackets from the kit pack should be fitted 
to the sides of the unit as shown in the illustration below. 

 

Once the brackets are securely fitted, the unit should be positioned so that the mounting 
holes in the brackets are aligned to the rack holes.  The unit should then be secured using 
captive fixings, to ensure the device is secured in the rack assembly.  Note – if you are using 
the rear GND terminal, then you may have to attach your Ground Cable before installing the 
unit into the rack, depending upon whether or not your rack has an open rear access panel 
or door. 

 

 

 

 

 

Содержание PDT-NSU-7216-PA-SF-R

Страница 1: ...Operations Manual PDT NSU 7216 PA SF R Revision 1 0 April 2022...

Страница 2: ...5 1 AI VLAN Mode 6 5 2 AI Extend Mode 6 5 3 AI Power Supply Mode 6 5 4 AI QoS Mode 6 6 Connectors and Configuration Options 7 6 1 LED Indicators 7 6 2 Mode Selection Switches 7 6 3 SFP Ports 8 6 4 RJ4...

Страница 3: ...1 Revision History Date Rev By Comments Checked Date 20 04 2022 01 JF Initial Release SC 22 04 2022...

Страница 4: ...elligence AP Access Point IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device PoE Power over Ethernet PSU Power Supply Unit QoS Q...

Страница 5: ...The Unit should be mains fed using the supplied AC Power Lead which is fitted with a 3A Fuse If the device is to be fed from an alternative power source then the appropriate circuit protection device...

Страница 6: ...t Passive PoE Switch 1 x Rackmount Kit 1 x Mains AC Power Lead Operation Maintenance Manual Declaration of Conformity 5 Product Overview The PDT NSU 7216 PA SF R is an Unmanaged Gigabit AI Passive PoE...

Страница 7: ...able where the power source is too far away for conventional configurations but the bandwidth limitation should not be overlooked when incorporating this feature into network designs 5 3 AI Power Supp...

Страница 8: ...Tx Rx SPD Port Data Rate Green OFF 10 100 Mbps ON 1000 Mbps 6 2 Mode Selection Switches The Mode Selection Switches toggle AI functionality modes as follows AI VLAN Mode Isolates Ports 1 16 from each...

Страница 9: ...onnectivity to a range of suitable peripherals PoE Power is provided on the RJ45 pins as follows Pins Type 4 5 24VDC 7 8 GND Rear Panel 6 5 GND Terminal The Unit incorporates an external GND terminal...

Страница 10: ...n below Once the brackets are securely fitted the unit should be positioned so that the mounting holes in the brackets are aligned to the rack holes The unit should then be secured using captive fixin...

Страница 11: ...e carrying pins continuously and users should check that all PoE powered devices to be used are compatible with 24VDC supply voltage 8 3 SFP Connections The SFP Ports incorporated into this unit only...

Страница 12: ...47 616Mbps INTERFACE Wired 16 x RJ45 Optical 2 x SFP 1000 BASE X or 100 BASE FX PoE Standard IEEE 802 3af Mode B Port RJ45 Power Pin Assignment 4 5 7 8 PoE output 24VDC PoE Budget 300W Max ENVIRONMENT...

Страница 13: ...000 3 3 2013 Electro Static Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity...

Отзывы: