background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFICATION 

 

 

Electrical Safety   

EN 62368-1:2020+A11:2020 

Emissions   

EN 55032:2015+A1:2020 

Radiated Immunity   

EN 55035:2017+A1:2020 

Harmonic Emissions   

EN 61000-3-2:2014 

Fluctuations and Flicker   

EN 61000-3-3:2013 

Electro-Static Discharge   

EN 61000-4-2:2009 

Electromagnetic Field Immunity   

EN 61000-4-3:2010 

Electrical Fast-Transients   

EN 61000-4-4:2012 

Surge   

EN 61000-4-5:2014+A1:2017 

Conducted Immunity   

EN 61000-4-6:2014 

Power Frequency Magnetic Field   

EN 61000-4-8:2010 

   

 

RoHS   

IEC 63000:2018 

 

 

 

For all technical enquiries regarding this product, please contact our technical support team using the 
following email address: 

 

[email protected]

 

 

 

 

 

 

 

 

 

 

 

Содержание PDT-NSU-7208-MP-SF-I

Страница 1: ...Operations Manual PDT NSU 7208 MP SF I Revision 1 0 March 2023...

Страница 2: ...iew 5 6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 RJ45 Ports 7 6 3 Power Supply Connector 7 6 4 PoE Output 7 6 5 PoE Budget 7 7 Installation Procedures 8 7 1 DIN Rail Installation 8 7 2 Wal...

Страница 3: ...1 Revision History Date Rev By Comments Checked Date 14 03 2023 01 JF Initial Release SC 14 03 2023...

Страница 4: ...ption AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device PoE Power o...

Страница 5: ...arty To prevent possible danger damage and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings...

Страница 6: ...Switch supporting 8 x 10 100 1000 BASE T PoE RJ45 Ports and 2 x 1000 BASE X auto detecting SFP Ports supporting 1 or 2 core Single Mode or Multi Mode Fiber The unit is designed for harsh industrial c...

Страница 7: ...tch and the associated port connections as indicated in the table below LED Name Colour State Status PWR Power Source Green OFF Power Not Avail ON Power Available FX1 2 Fiber Link Green OFF SFP Not Co...

Страница 8: ...ice is designed to be supplied by a 48VDC power supply but can operate in the range 48 57VDC Power is supplied via a 6 pin terminal block connector with the following pinout Note All Power Supplies sh...

Страница 9: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Страница 10: ...ports TP1 4 are available for other devices or connections All cables should be solid copper and not CCA 8 3 SFP Port Connections Ensure that the SFP socket is clear from any dirt or contamination an...

Страница 11: ...9 Physical Dimensions...

Страница 12: ...g Rate 14 88Mbps INTERFACE Wired 8 x 10 100 1000 BASE T RJ45 Fiber 2 x 1000 BASE FX SFP PoE Standard IEEE 802 3af IEEE 802 3at Port Type RJ45 Power Pin Assignment 4 5 7 8 Power Budget 240W Max ENVIRON...

Страница 13: ...tic Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity EN 61000 4 6 2014 Power...

Отзывы: