background image

 

 

 

 

6.2

 

  RJ45 Ports 

 

The Front Panel has 2 RJ45 Ports and which are all 10/100/1000 BASE-T Ports 

 note that these 

are all PoE+ capable ports, in accordance with the IEEE 802.3at Standard.  All of the RJ-45 ports 
are auto MDI/MDI-X compatible and can operate in Full/Half Duplex Modes via auto-negotiation. 
The remaining SFP port is 100/1000 BASE-FX and accept a wide range of SFP modules. 

 

6.3

 

  Power Connections 

 

Model 

V- 

V+ 

Power Input 

PDT-NSU-7102-MP-SF-I 

GND 

12-48VDC 

 
 
 
 

 

 

Note: All Power Supplies should provide over-current and short-circuit protection and should 
have a capacity rating to meet the required output current for the device. 

 

6.4

 

  PoE Output 

 

Model 

802.3af 

802.3at 

802.3bt 

PDT-NSU-7102-MP-SF-I 

 

 

 

 

 

6.5

 

  PoE Budget 

 

The total PoE Power Budget for this product is independent of input voltage and is fixed at 60W 
total.

 

 

 

 

Содержание PDT-NSU-7102-MP-SF-I

Страница 1: ...Operations Manual PDT NSU 7102 MP SF I Revision 2 0 March 2023...

Страница 2: ...erview 5 6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 RJ45 Ports 7 6 3 Power Connections 7 6 4 PoE Output 7 6 5 PoE Budget 7 7 Installation Procedures 8 7 1 DIN Rail Installation 8 7 2 Wall...

Страница 3: ...1 Revision History Date Rev By Comments Checked Date 09 03 2023 01 JF Initial Release SC 10 03 2023...

Страница 4: ...ption AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device PoE Power o...

Страница 5: ...arty To prevent possible danger damage and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings...

Страница 6: ...supporting 2 x 10 100 1000 BASE T RJ45 Ports and 1 x 100 1000 BASE FX SFP Ports with the 2 x RJ45 Ports being PoE capable 802 3at This model can operate on input voltages from 12 48VDC and the device...

Страница 7: ...ns as indicated in the table below LED Name Colour State Status PWR Power Source Green OFF Power Not Avail ON Power Available FX Fiber Link Green ON SFP Connected OFF SFP Not Connected NC N A Green N...

Страница 8: ...aining SFP port is 100 1000 BASE FX and accept a wide range of SFP modules 6 3 Power Connections Model V V Power Input PDT NSU 7102 MP SF I GND 12 48VDC Note All Power Supplies should provide over cur...

Страница 9: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Страница 10: ...ports TP1 4 are available for other devices or connections All cables should be solid copper and not CCA 8 3 SFP Port Connections Ensure that the SFP socket is clear from any dirt or contamination an...

Страница 11: ...9 Physical Dimensions...

Страница 12: ...ERFACE Wired 2 x 10 100 BASE T RJ45 Fiber 1 x 1000 BASE FX SFP PoE Standard IEEE 802 3af IEEE 802 3at Port Type RJ45 Power Pin Assignment 4 5 7 8 Power Budget 48VDC Supply 120W 24VDC Supply 90W 12VDC...

Страница 13: ...tic Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity EN 61000 4 6 2014 Power...

Отзывы: