Parallax PDT-NSU-0008-MP-I Скачать руководство пользователя страница 10

 

 

 

8.

 

Connection and Setup 

 

8.1

 

  Inspection Checks 

 

Please inspect the unit to ensure that there is no damage to the external casing which could cause a 
malfunction of the device or cause a safety critical fault.  Any damaged units should be returned to Parallax 
Digital Technologies for inspection and testing. 

Please ensure that the DC Cables are securely fastened in the terminal block, and that the terminal block is 
correctly inserted into the switch power connector housing. 

 

8.2

 

  RJ45 Connections 

 

Ensure all required RJ45 Ports are connected correctly using CAT5e cable or better to the client devices.  
The Uplink port should be connected to the host device or network, and the access ports are available for 
other devices or connections. All cables should be solid copper and not CCA. 

 

8.3

 

  Power Up  

 

The Unit will automatically power up as soon as DC power is applied to the device. The Power Light will be 
illuminated and after approximately 1 second, all of the other LEDs will flash on and off to complete the 
initialization sequence.  Following this, the Port Status LEDs will display the current state of each of the 
ports. 

 

9.

 

Physical Dimensions 

 

 

All Dimensions are in mm 

 

Содержание PDT-NSU-0008-MP-I

Страница 1: ...Operations Manual PDT NSU 0008 MP I Revision 1 0 March 2023...

Страница 2: ...5 6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 RJ45 Ports 6 6 3 Power Supply Connector 7 6 4 PoE Compatibility 7 6 5 PoE Power Budget 7 7 Installation Procedures 8 7 1 DIN Rail Installation...

Страница 3: ...1 Revision History Date Rev By Comments Checked Date 09 03 2023 01 JF Initial Release SC 09 03 2023...

Страница 4: ...ption AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device PoE Power o...

Страница 5: ...and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings and cautionary statements could lead to...

Страница 6: ...IP Telephones etc This model operates from a nominal 48VDC power supply but can utilize supplies in the range 48 57VDC The device is designed for use in harsh industrial environments and incorporating...

Страница 7: ...connections as indicated in the table below LED Name Colour State Status PWR Power Green OFF Unit Power Off ON Unit Power On T1 8 Link Activity Green OFF No Connection Flashing Connection FX1 2 Not Us...

Страница 8: ...meet the required output current for the device plus any PoE powered device requirements 6 4 PoE Compatibility Model No IEEE 802 3af IEEE 802 3at IEEE 802 3bt PDT NSU 0008 MP I The PoE output for this...

Страница 9: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Страница 10: ...onnections Ensure all required RJ45 Ports are connected correctly using CAT5e cable or better to the client devices The Uplink port should be connected to the host device or network and the access por...

Страница 11: ...ng Rate 14 88Mbps INTERFACE Wired 8 x 10 100 1000 PoE RJ45 PoE Standard IEEE 802 3af 802 3at Port RJ45 Power Pin Assignment 4 5 7 8 PoE Budget 240W ENVIRONMENTAL Operating Temperature 40 C to 80 C Sto...

Страница 12: ...tic Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity EN 61000 4 6 2014 Power...

Отзывы: