7300 Series
DC Wiring
1.
Converter DC output lead.
2.
Converter “reverse battery polarity”
protection fuses.
3.
“C” Terminal – Connect to battery
Positive wiring. # 8 CU AWG
minimum w/ 90 degree Celsius
insulation rating required.
4.
“D” Terminal – Connect to 12 volt
load Negatives and battery Negative.
# 8 CU AWG minimum w/ 90 degree
Celsius insulation rating required.
5.
12 Volt load circuit Positive
connection terminals. Fuse each load
circuit per NEC Code (Table 310-16)
appropriate to AWG and temperature
rating of conductor used.
12 VDC installation shall comply with
ANSI/RVIA 12 V
GR series terminal bar
recommended.
DC load circuits
+
+
1
2
3
4
5
+
Product shown with Door and dead front plate removed.