3.2  Do  not  use  harsh  chemicals  to  clean  the 

heating  element.  Harsh  chemicals  may 
cause corrosion. 

  

THE STEAM PIPE & NOZZLE  

                      .

 

  

4.1  Check  to  see  that  the  steam  pipe  is 

aligned  with  the  plastic circular  nozzle.    If 
needed,  realign  the  steam  pipe  w/  the 
nozzle. 

 

Figure 4.1             

 

 

 

 

 

       Cap Screw 

 

 

 

 

 

 

 

 

 

 

      

Steamer Cap 

 
 
 

 

 

 

 

      

Nozzle Cap 

 

 

 

 

 

       

 

 

 

 

 

      

Steam Pipe 

 

 

 

 

 

 

 

 

 

 

 

      

Yellow Nozzle 

Sponge

 

  

 

 
 

4.2  Realigning the steam pipe 

4.2.1 You will need a screw driver and a 

7mm nut driver 

4.2.2 Remove  the  screw  securing  the 

plastic cap at the top of the steam 
arm. 

4.2.3 Loosen the two screws  located on 

the center strip.   

4.2.4 Loosen  the  7mm  nut  located 

slightly  underneath  the  center 
strip. 

 

  

Figure 4.2.3 
   

     4.2.4 

 

 

 

 

 

 

2 screws 

(Below the 

 

 

 

 

 

 Steamer Cap)

 

   

 
 
 

 

 

 

 

 

7mm nut 

  

 

 
 
 
 
 

 

 

 

 

 

4.2.5 Insert  another  screw  driver,  into 

the opening of the steam pipe. 

4.2.6 Gently  adjust  the  steam  pipe  to 

align with the nozzle. 

4.2.7 Tightened the 2 screws & nut. 
4.2.8 Reattach  the  plastic  steamer  arm 

cap. 

  

4.3  Replace  the  nozzle  sponge  as  needed. 

(

item  no.  101-NOZL/STR

)  The  nozzle  sponge 

helps  in  trapping  and  absorbing  larger 
droplets of water.  It is recommended that 
the nozzle strip be changed as needed or 
once  every  six  months.  This  nozzle 
sponge lies beneath the plastic nozzle cap 
and  is  different  from  the  Aroma  Therapy 
(AT-1) 

attachment 

that 

also 

has 

disposable strips for aroma therapy.   

  

Note:  Placing  oils  on  the  nozzle  sponge  will 

decreases  its  effectiveness  by  making  it 
more repellant to water. 

  

4.4  Cleaning the Steam Pipe 

4.4.1 You may need an X-acto knife with 

a  triangular  blade  &  some  Q-tips.  
Please use caution when  handling 
sharp knives. 

4.4.2 Unscrew the plastic circular nozzle 

cap and nozzle sponge. 

4.4.3 Insert  the  X-acto  knife  into  the 

steam pipe opening. 

 
 

        Figure 4.4.3 
                    4.4.4 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

4.4.4 Using  a  circular  motion,  remove 

mineral build-up by scraping the X-
acto knife along the inside surface 
diameter of the Steam Pipe. 

4.4.5 With  a  Q-tip,  remove  any  loose 

debris. 

4.4.6 Reattach the nozzle cap & sponge. 

 

 

*Drawings are not to scale.

 

 

 

 