Paradyne UIM-10/100 Скачать руководство пользователя страница 2

2

 August 

2005

UIM1-A2-GZ40-00

Using the UIM an IP DSLAM

Use of the UIM in a multi-slot IP DSLAM requires that you install the UIM in a 
Multiplexer Uplink Module (MUM), then install the MUM in the DSLAM chassis.

Installing the UIM in a MUM

The UIM may be attached to a MUM that has already been in service, although 
you must remove the MUM from the IP DSLAM in order to do so. Removal of a 
MUM from an IP DSLAM chassis that is powered up will not affect the operational 
status of other modules within the chassis; it will, however, disengage the IP 
DSLAM's upstream network connection.

Procedure

To install the UIM:

1. Place the MUM on a flat surface with the circuit board facing up.

2. Select a port on the MUM for UIM installation; either port (1 or 2) may be used. 

Although not required for operational purposes, if redundancy is desired, two 
UIMs may be installed on the MUM.

3. Remove the slot cover from the selected port.

Store slot covers for possible future use. If a UIM is removed from a MUM, it 
must be replaced with either another UIM or a slot cover. Do not install a MUM 
with an open UIM port into an IP DSLAM.

4. Carefully slide the faceplate of the UIM under the lip of the MUM faceplate at 

the selected port opening such that the UIM circuit board is face down and the 
UIM label shows through the port opening with the model name along the right 
side.

5. Ensure the mounting holes on the UIM are lined up with the corresponding 

standoffs on the MUM and the board-to-board connector key pins are properly 
aligned.

6. Gently press down with even pressure on all four corners of the UIM until the 

board-to-board connector is fully seated.

7. Secure the boards together at the standoffs with the four provided panhead 

screws.

8. Secure the UIM faceplate to the MUM faceplate using the two provided  

flathead screws.

Содержание UIM-10/100

Страница 1: ...IVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge ESD during normal operation When performing installation procedures however take proper static control precautions to prevent damage to equipment If you are not sure of the proper static control precautions contact your nearest sales or service representative Unpack and inspect the equip...

Страница 2: ...s if redundancy is desired two UIMs may be installed on the MUM 3 Remove the slot cover from the selected port Store slot covers for possible future use If a UIM is removed from a MUM it must be replaced with either another UIM or a slot cover Do not install a MUM with an open UIM port into an IP DSLAM 4 Carefully slide the faceplate of the UIM under the lip of the MUM faceplate at the selected po...

Страница 3: ...ight screws securing the Mini DSLAM chassis and carefully lift off the chassis cover Set the screws aside 2 Select a port on the Mini DSLAM for UIM installation either port 1 or 2 may be used Although not required for operational purposes if redundancy is desired two UIMs may be installed in the Mini DSLAM 3 Remove the slot cover from the selected port Store slot covers for possible future use If ...

Страница 4: ...on of the Lnk LED on the UIM faceplate indicates an Ethernet link has been established If the Lnk LED is illuminated but not the 100 LED then a 10 Mbps link has been established If the 100 LED is also illuminated then a 100 Mbps link has been established For most applications the UIM 10 100 connects to a router or a PC using a straight through Ethernet cable and to a hub or a switch using a crosso...

Страница 5: ...e current information by fax or to speak with a company representative Within the U S A call 1 800 795 8004 Outside the U S A call 1 727 530 2340 Table 2 LEDs LED State Meaning Additional Information 100 solid green Fast Ethernet connection 100 Mbps is established If the 100 LED is illuminated the Lnk LED will also be illuminated no illumination no Fast Ethernet connection If the 100 LED remains u...

Страница 6: ...ation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation If the equipment ...

Отзывы: