LED Indicators

Table 1. LEDs

LED

STATE

INDICATION

ADDITIONAL 
INFORMATION

T1 Connections 
(Port 1 Lnk and Port 2 
Lnk)

Flashing  Green*

T1 connection is established 
and active.

Traffic is flowing.

Solid Green

Problematic T1 connection.

A connection exists but there is 
indication of a problem with the 
T1 line.

No Illumination

Red AlarmThe incoming 
connection to the MIM-2T1 
has been lost; no data is 
being received.

If the outgoing connection from 
the MIM-2T1 has also been lost 
then the remote T1 equipment 
to which the MIM is connected 
will be in Red Alarm as well.

T1 Alarms (Port 1 
Alm and Port 2 Alm)

No Illumination

T1 is operational

An established T1 link is 
operational and has no alarm 
indications unless the T1 Lnk 
LED remains unlit as well, in 
which case the MIM-2T1 is in 
Red Alarm.

Solid Amber

Yellow Alarm. The outgoing 
connection from the 
MIM-2T1 has been lost; no 
data is being transmitted.

The remote T1 equipment has 
lost its incoming connection 
and is in Red Alarm.

Pulsing Amber

Blue Alarm. An indirect 
connection has been lost; 
the MIM-2T1 may no longer 
be receiving data from the 
remote T1 equipment.

The remote T1 equipment has 
lost a connection with an 
intermediate device and is in 
Red or Yellow Alarm.

*

A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, 
less constant rate.

Содержание MIM-2T1

Страница 1: ...including any copy of either If you have executed a separate written agreement covering the Software supplied to you under this purchase such separate written agreement shall govern Paradyne Corporati...

Страница 2: ...HOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT Some states or other jurisdictions do not allow the exclusion of implied warranties on limit...

Страница 3: ...t attempt to install the MIM 2T1 contact your sales representative Installing the MIM 2T1 The MIM 2T1 Micro Interface Module provides additional uplink ports for the A D8000 ADSL Micro DSLAM or BSX800...

Страница 4: ...ed A MIM 2T1 can only establish loop bonded connections with other loop bonding capable T1 provider equipment refer to the T1 Loop Bonding Product to Product Feature Compatibility list Document Number...

Страница 5: ...errite choke Position the choke as close as possible to the RJ45 connector Snap shut the ferrite choke 2 Plug your T1 cable into one of the two T1 RJ45 ports on the MIM 2T1 Either port may be used 3 V...

Страница 6: ...as well the two ports cannot be configured independently Refer to the NMS User s Guide Document Number NMS A2 GB20 for more detailed instructions Frame Type Frame type is the T1 data encapsulation me...

Страница 7: ...trings of zeros which can potentially cause loss of synchronization between units Paradyne products meet the North American minimum ones density requirement internally such that loss of synchronizatio...

Страница 8: ...rm as well T1 Alarms Port 1 Alm and Port 2 Alm No Illumination T1 is operational An established T1 link is operational and has no alarm indications unless the T1 Lnk LED remains unlit as well in which...

Страница 9: ...ired to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or...

Страница 10: ...ng distributor locations or Paradyne worldwide office locations use one of the following methods Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty a...

Отзывы: