February 2003
3-61
1000-A2-GH30-00
3. TL1 Commands and Messages
Table 3–32.Retrieve OC3 Parameters and Description
Parameter
Parameter Type
Description
oc_id
This parameter specifies the AID for optical
carrier facility.
oc_id
is the AID OC and is listable
and rangeable.
oc_id
must not be null.
type
Type
This parameter identifies the type of entity being
provisioned. Null indicates not applicable. This
parameter can be a common language equipment
identifier (CLEI) code or some other value.
type
is optional.
aisnc
NotificationCode
This parameter indicates the alarm status when a
VT path AIS is detected. If no value is specified,
aisnc
defaults to “not reported”.
aisnc
is optional.
dcc
BoolYN
This parameter indicates whether the section DCC
is used.
dcc
is optional.
ferfnc
NotificationCode
This parameter indicates the alarm status when a
far-end receive failure signal is detected. If no
value is specified,
ferfnc
defaults to “not alarmed
but reported.”
ferfnc
is optional.
gos
This parameter indicates the grade of service. A
value of 0 means that grade of service is not
applied to the provisioned facility. Other positive
integers refer to a grade of service.
gos
is an integer and optional.
sdh
BoolYN
This parameter establishes a high priority for the
OC in the event of a signal degrade. Default is N;
Y sets it to high.
sdh
is optional.
sfh
BoolYN
This parameter establishes a high priority for the
OC in the event of a signal failure. Default is N; Y
sets it to high.
sfh
is optional.