12
8786-A2-GZ40-20
February 2001
Table 3.
Copy Ports Options
From: Port n
Possible Settings: 1, 2
Default Setting: 1
Controls the source of the configuration options.
To: Port y
Possible Settings: 1, 2, All
Default Setting: 2
Controls the target of the configuration options.
NOTE:
Peer IP Address and Circuit Identifier are not copied.
Table 4.
System Options
DSL Mode
Possible Settings: LTU, NTU
Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
NOTE:
Changing this option will reset the unit.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed, so that control can be regained after a test is accidentally executed.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H
Test Duration (min) option appears when Test Timeout is enabled.
G.703 Line Termination
Possible Settings: 75 ohms, 120 ohms
Default Setting: 120 ohms
Specifies the impedance of the G.703 interface