Important Safety Instructions

1. Read and follow all warning notices and instructions marked on the product or

included in the manual.

2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable

operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.

3. Do not allow anything to rest on the power cord and do not locate the product

where persons will walk on the power cord.

4. Do not attempt to install or service this product yourself, as opening or removing

covers may expose you to dangerous high voltage points or other risks. Refer all
installation and servicing to qualified service personnel.

5. General purpose cables are provided with this product. Special cables, which may

be required by the regulatory inspection authority for the installation site, are the
responsibility of the customer.

6. When installed in the final configuration, the product must comply with the

applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.

7. A rare phenomenon can create a voltage potential between the earth grounds of

two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.

8. In addition, if the equipment is to be used with telecommunications circuits, take

the following precautions:

— Never install telephone wiring during a lightning storm.

— Never install telephone jacks in wet locations unless the jack is specifically

designed for wet locations.

— Never touch uninsulated telephone wires or terminals unless the telephone

line has been disconnected at the network interface.

— Use caution when installing or modifying telephone lines.

— Avoid using a telephone (other than a cordless type) during an electrical

storm. There may be a remote risk of electric shock from lightning.

— Do not use the telephone to report a gas leak in the vicinity of the leak.

Содержание Hotwire 8747

Страница 1: ...nation Units Models 8747 8777 and 8779 User s Guide To request a paper copy of a Paradyne document H Within the U S A call 1 800 PARADYNE 1 800 727 2396 H Outside the U S A call 1 727 530 8623 Hotwirer M SDSL and HDSL2 Termination Units The Hotwire 8747 8777 and 8779 Termination Units are circuit card assemblies that contain eight Multirate Symmetric Digital Subscriber Line M SDSL or High bit rate...

Страница 2: ...ke sure the Hotwire DSLAM chassis is installed and power is supplied to the chassis After the Hotwire 87xx Termination Unit is installed there are configuration procedures that must be performed before you can begin to use the termination unit Refer to the User s Guide for more detailed configuration procedures Cables You Need The following standard cables are used with this product For the networ...

Страница 3: ...r cards in the chassis Procedure To install the Hotwire 87xx Termination Unit 1 Determine in which slot the unit will be installed Verify that cards in adjacent slots have been fastened 2 Remove the filler plate from the installation slot and store for possible later use 3 Insert the unit For a Hotwire 8610 DSLAM chassis hold the Hotwire Termination Unit horizontally with component side facing up ...

Страница 4: ...3 S Y N C P O R T D S L P O R T L IN K U P 4 4 Slide the unit into the slot until the power and network connectors seat firmly in the mating connectors on the backplane CAUTION Do not force the unit into the slot This could damage the backplane connectors If the card does not seat properly remove the card and reinstall it If it still does not seat properly call your service representative The unit...

Страница 5: ... cable ties to the rack DSLAM or Cable Guide 6 Connect the terminating connectors to your DTEs Connecting to an MDF You can connect the Hotwire DSLAM chassis containing the Hotwire 87xx Termination Unit to an MDF or other demarcation point Do not connect it to a POTS splitter Procedure To connect the Hotwire DSLAM chassis containing the unit to an MDF 1 Plug the Telco 50 pin cable into the appropr...

Страница 6: ...ms Test Amber On Slow cycling Off Loopback test or 511 test pattern in progress POST in progress No tests PORTS when DSX 1 or G 703 selected 1 8 Green On Slow cycling Fast cycling Off Recoverable signal present on the network Yellow Alarm Indication DSX 1 or Remote Alarm Indication G 703 An OOF LOF EER or AIS condition exists No signal on the port PORTS when DSL selected 1 8 Green On Slow cycling ...

Страница 7: ...ion Unit menu to display or change configuration option settings The unit is shipped with factory settings in the Default Factory Configuration area If the factory default settings do not support your network s configuration customize the configuration options for your application Accessing and Displaying Configuration Options To display the configuration options you must first load a configuratio...

Страница 8: ...ace Options G 703 Interface Options DSX 1 interface ports Models 8747 and 8777 G 703 interface ports Model 8779 Copy Ports Copy Ports Options DSL network and DTE interface ports by copying options from port to port System Options System Options General system options of the unit System Clock System Clock Options LTU system clock options Cross Connect Cross Connect Mode Options Assign Time Slots Op...

Страница 9: ...uration Control Change Identity Administer Logins Download Code Apply Download Port LEDs 99 16607 Reset AutoRate DSX 1 G 703 Statistics Reset Device Default Factory Configuration Configuration Loader Current Configuration Edit Display Network DSX 1 G 703 Copy Ports System Options Management and Communication Telnet Session General SNMP Management SNMP NMS Security SNMP Traps System Clock Cross Con...

Страница 10: ... of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical...

Страница 11: ...ulations Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada Warranty Sales Service and Training Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor lo...

Отзывы: